y Both the authors contributed equally.We compared cold static with acellular normothermic ex vivo liver perfusion (NEVLP) as a novel preservation technique in a pig model of DCD liver injury. DCD livers (60 min warm ischemia) were cold stored for 4 h, or treated with 4 h cold storage plus 8 h NEVLP. First, the livers were reperfused with diluted blood as a model of transplantation. Liver injury was determined by ALT, oxygen extraction, histology, bile content analysis and hepatic artery (HA) angiography. Second, AST levels and bile production were assessed after DCD liver transplantation. Cold stored versus NEVLP grafts had higher ALT levels (350 AE 125 vs. 55 AE 35 U/L; p < 0.0001), decreased oxygen extraction (250 AE 65 mmHg vs. 410 AE 58 mmHg, p < 0.01) and increased hepatocyte necrosis (45% vs. 10%, p ¼ 0.01). Levels of bilirubin, phospholipids and bile salts were fivefold decreased, while LDH was sixfold higher in cold stored versus NEVLP grafts. HA perfusion was decreased (twofold), and bile duct necrosis was increased (100% vs. 5%, p < 0.0001) in cold stored versus NEVLP livers. Following transplantation, mean serum AST level was higher in the cold stored versus NEVLP group (1809 AE 205 U/L vs. 524 AE 187 U/L, p < 0.05), with similar bile production (2.5 AE 1.2 cc/h vs.2.8 AE 1.4 cc/h; p ¼ 0.2). NEVLP improved HA perfusion and decreased markers of liver duct injury in DCD grafts.
The purpose of this study was to evaluate a whole-organ perfusion protocol of the pancreas in patients with primary pancreas carcinoma and to analyse perfusion differences between normal and diseased pancreatic tissue. Thirty patients with primary pancreatic malignancy were imaged on a 320-slice CT unit. Twenty-nine cancers were histologically proven. CT data acquisition was started manually after contrast-material injection (8 ml/s, 350 mg iodine/ml) and dynamic density measurements in the right ventricle. After image registration, perfusion was determined with the gradient-relationship technique and volume regions-of-interest were defined for perfusion measurements. Contrast time-density curves and perfusion maps were generated. Statistical analysis was performed using the Kolmogorov-Smirnov test for analysis of normal distribution and Kruskal-Wallis test (nonparametric ANOVA) with Bonferroni correction for multiple stacked comparisons. In all 30 patients the entire pancreas was imaged, and registration could be completed in all cases. Perfusion of pancreatic carcinomas was significantly lower than of normal pancreatic tissue (P < 0.001) and could be visualized on colored perfusion maps. The 320-slice CT allows complete dynamic visualization of the pancreas and enables calculation of whole-organ perfusion maps. Perfusion imaging carries the potential to improve detection of pancreatic cancers due to the perfusion differences.
To evaluate two MR imaging sequences for the detection of artificial pulmonary nodules inside porcine lung explants. 67 agarose nodules ranging 3-20 mm were injected into ten porcine lungs within a dedicated chest phantom. The signal on T1-weighted images and radiopacity were adjusted by adding 0.125 mmol/l Gd-DTPA and 1.5 g/l of iodine. A T1-weighted three-dimensional gradient-echo (T1-3D-GRE; TR/TE:3.3/1.1 ms, slice:8 mm, flip-angle:10 degrees ) and a T2-weighted half-Fourier fast-spin echo sequence (T2-HF-FSE; TR/TE:2000/66 ms, slice:7 mm, flip-angle:90 degrees ) were applied in axial orientation using a 3-T system (Intera, Philips Medical Systems, Best, The Netherlands), followed by CT (16x0.5 mm) as reference. Nodule sizes and locations were assessed by three blinded observers. In nodules of >10 mm, sensitivity was 100% using 3D-GRE-MRI and 94% using the HF-FSE sequence. For nodules 6-10 mm, the sensitivity of MRI was lower than with CT (3D-GRE:92%; T2-HF-FSE:83%). In lesions smaller than 5 mm, the sensitivity declined to 80% (3D-GRE) and 53% (HF-FSE). Small lesion diameters were overestimated with both sequences, particularly with HF-FSE. This study confirms the feasibility of 3 T-MRI for lung nodule detection. In lesions greater than 5 mm, the sensitivity of the 3D-GRE sequence approximated CT (>90%), while sensitivity and PPV with the HF-FSE sequence were slightly inferior.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.