Background
In 2017, we established an airway call (AC) team composed of anesthesiologists to improve emergency airway management outside the operating room. In this retrospective analysis of prospectively collected data from the airway registry, we describe the characteristics of patients attended to and practices by the AC team during the first 4 years of implementation.
Methods
All AC team activations in which an airway intervention was performed by the AC team between June 2017 and May 2021 were analyzed.
Results
In all, 359 events were analyzed. Activation was more common outside of working hours (62.1%) and from the intensive care unit (85.0%); 36.2% of AC activations were due to known or anticipated difficult airway, most commonly because of acquired airway anomalies (n = 49), followed by airway edema or bleeding (n = 32) and very young age (≤ 1 years; n = 30). In 71.3% of the cases, successful intubation was performed by the AC team at the first attempt. However, three or more attempts were performed in 33 cases. The most common device used for successful intubation was the videolaryngoscope (59.7%). Tracheal intubation by the AC team failed in nine patients, who then required surgical airway insertion by otolaryngologists. However, there were no airway-related deaths.
Conclusions
When coupled with appropriate assistance from an otolaryngologist AC system, an AC team composed of anesthesiologists could be an efficient way to provide safe airway management outside the operating room.
Trial Registration
Clinical Research Information Service Identifier:
KCT0006643
Background: Pacemakers assist circulation by generating electrical impulses. Patients with pacemakers scheduled to undergo surgery are vulnerable to device-related complications. Therefore, careful perioperative management is required to prevent undesirable events.Case: A 66-year-old man with alcohol-related hepatocellular carcinoma was referred for liver transplantation. The pacemaker was inserted preoperatively to manage sick sinus syndrome and paroxysmal atrial fibrillation. Overall liver transplantation was performed without any adverse events. However, the pacemaker suddenly failed to provide regular pacing rhythm during abdominal closure. Fortunately, the native heart rate was maintained above 70 beats per minute and blood pressure did not fluctuate after pacing failure. After retrospective analysis, the duration setting of preoperative pacemaker reprogramming (24 h) was revealed as the cause of unexpected pacing failure.Conclusions: Anesthesiologists should be alert in patients with pacemakers because minor errors may lead to inadvertent failure of pacing or severe hemodynamic instability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.