Background Cardiac time-resolved CT (4D-CT) acquisitions provide high quality anatomical images of the heart. However, some cardiac diseases require assessment of blood flow in the heart. Diastolic dysfunction, for instance, is diagnosed by measuring the flow through the mitral valve (MV), while in atrial fibrillation, the flow through the left atrial appendage (LAA) indicates the risk for thrombus formation. Accurate validated techniques to extract this information from 4D-CT have been lacking, however. Methods To measure the flow rate though the MV and the LAA from 4D-CT, we developed a motion tracking algorithm that performs a nonrigid deformation of the surface separating the blood pool from the myocardium. To improve the tracking of the LAA, this region was deformed separately from the left atrium and left ventricle. We compared the CT based flow with 4D flow and short axis MRI data from the same individual in 9 patients. Results For the mitral valve flow, good agreement was found for the time span between the early and late diastolic peak flow (bias: <0.1 s). The ventricular stroke volume is similar compared to short-axis MRI (bias 3 ml). There are larger differences in the diastolic peak flow rates, with a larger bias for the early flow rate than the late flow rate. The peak LAA outflow rate measured with both modalities matches well (bias: −6 ml/s). Conclusions Overall, the developed algorithm provides accurate tracking of dynamic cardiac geometries resulting in similar flow rates at the MV and LAA compared to 4D flow MRI.
IntroductionAtrial fibrillation (AF) is associated with an increased risk of stroke, often caused by thrombi that form in the left atrium (LA), and especially in the left atrial appendage (LAA). The underlying mechanism is not fully understood but is thought to be related to stagnant blood flow, which might be present despite sinus rhythm. However, measuring blood flow and stasis in the LAA is challenging due to its small size and low velocities. We aimed to compare the blood flow and stasis in the left atrium of paroxysmal AF patients with controls using computational fluid dynamics (CFD) simulations.MethodsThe CFD simulations were based on time-resolved computed tomography including the patient-specific cardiac motion. The pipeline allowed for analysis of 21 patients with paroxysmal AF and 8 controls. Stasis was estimated by computing the blood residence time.Results and DiscussionResidence time was elevated in the AF group (p < 0.001). Linear regression analysis revealed that stasis was strongest associated with LA ejection ratio (p < 0.001, R2 = 0.68) and the ratio of LA volume and left ventricular stroke volume (p < 0.001, R2 = 0.81). Stroke risk due to LA thrombi could already be elevated in AF patients during sinus rhythm. In the future, patient specific CFD simulations may add to the assessment of this risk and support diagnosis and treatment.
Difficulties in achieving knowledge about physiology and anatomy of the beating heart highlight the challenges with more traditional pedagogical methods. Recent research regarding anatomy education has mainly focused on digital three‐dimensional models. However, these pedagogical improvements may not be entirely applicable to cardiac anatomy and physiology due to the multidimensional complexity with moving anatomy and complex blood flow. The aim of this study was therefore to evaluate whether high quality time‐resolved anatomical images combined with realistic blood flow simulations improve the understanding of cardiac structures and function. Three time‐resolved datasets were acquired using time‐resolved computed tomography and blood flow was computed using Computational Fluid Dynamics. The anatomical and blood flow information was combined and interactively visualized using volume rendering on an advanced stereo projection system. The setup was tested in interactive lectures for medical students. Ninety‐seven students participated. Summative assessment of examinations showed significantly improved mean score (18.1 ± 4.5 vs 20.3 ± 4.9, p = 0.002). This improvement was driven by knowledge regarding myocardial hypertrophy and pressure–velocity differences over a stenotic valve. Additionally, a supplementary formative assessment showed significantly more agreeing answers than disagreeing answers (p < 0.001) when the participants subjectively evaluated the contribution of the visualizations to their education and knowledge. In conclusion, the use of simultaneous visualization of time‐resolved anatomy data and simulated blood flow improved medical students' results, with a particular effect on understanding of cardiac physiology and these simulations may be useful educational tools for teaching complex anatomical and physiological concepts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.