ObjectivesOur aim was to evaluate systemic lupus erythematosus (SLE) disease activity and SARS-CoV-2-specific immune responses after BNT162b2 vaccination.MethodsIn this prospective study, disease activity and clinical assessments were recorded from the first dose of vaccine until day 15 after the second dose in 126 patients with SLE. SARS-CoV-2 antibody responses were measured against wild-type spike antigen, while serum-neutralising activity was assessed against the SARS-CoV-2 historical strain and variants of concerns (VOCs). Vaccine-specific T cell responses were quantified by interferon-γ release assay after the second dose.ResultsBNT162b2 was well tolerated and no statistically significant variations of BILAG (British Isles Lupus Assessment Group) and SLEDAI (SLE Disease Activity Index) scores were observed throughout the study in patients with SLE with active and inactive disease at baseline. Mycophenolate mofetil (MMF) and methotrexate (MTX) treatments were associated with drastically reduced BNT162b2 antibody response (β=−78, p=0.007; β=−122, p<0.001, respectively). Anti-spike antibody response was positively associated with baseline total immunoglobulin G serum levels, naïve B cell frequencies (β=2, p=0.018; β=2.5, p=0.003) and SARS-CoV-2-specific T cell response (r=0.462, p=0.003). In responders, serum neutralisation activity decreased against VOCs bearing the E484K mutation but remained detectable in a majority of patients.ConclusionMMF, MTX and poor baseline humoral immune status, particularly low naïve B cell frequencies, are independently associated with impaired BNT162b2 mRNA antibody response, delineating patients with SLE who might need adapted vaccine regimens and follow-up.
Photonic ring resonance is a property of light where in certain circumstances specific wavelengths are trapped in a ring resonator. Sensors based on silicon photonic ring resonators function by detecting the interaction between light circulating inside the sensor and matter deposited on the sensor surface. Binding of biological material results in a localized change in refractive index on the sensor surface, which affects the circulating optical field extending beyond the sensor boundary. That is, the resonant wavelength will change when the refractive index of the medium around the ring resonator changes. Ring resonators can be fabricated onto small silicon chips, allowing development of a miniature multiplex array of ring based biosensors. This paper describes the properties of such a system when responding to the refractive index changed in a simple and precise way by changing the ionic strength of the surrounding media, and in a more useful way by the binding of macromolecules to the surface above the resonators. Specifically, a capture immunoassay is described that measures the change of resonant wavelength as a patient serum sample with anti-SS-A autoantibodies is flowed over a chip spotted with SS-A antigen and amplified with anti-IgG. The technology has been miniaturized and etched into a 4×6mm silicon chip that can measure 32 different reactions in quadruplicate simultaneously. The variability between 128 rings on a chip as measured by 2M salt assays averaged 0.6% CV. The output of the assays is the average shift per cluster of 4 rings, and the assays averaged 0.5% CV between clusters. The variability between chips averaged 1.8%. Running the same array on multiple instruments showed that after some improvements to the wavelength referencing system, the upper boundary of variation was 3% between 13 different instruments. The immunoassay displayed about 2% higher variability than the salt assays. There are several outstanding features of this system. The amount of antigen used on the chip for each test is around 200 picograms, only a few microliters of sample is necessary, and the assays take <10min.
The capacity of pre-existing immunity to human common coronaviruses (HCoV) to cross-protect against de novo COVID-19is yet unknown. In this work, we studied the sera of 175 COVID-19 patients, 76 healthy donors and 3 intravenous immunoglobulins (IVIG) batches. We found that most COVID-19 patients developed anti-SARS-CoV-2 IgG antibodies before IgM. Moreover, the capacity of their IgGs to react to beta-HCoV, was present in the early sera of most patients before the appearance of anti-SARS-CoV-2 IgG. This implied that a recall-type antibody response was generated. In comparison, the patients that mounted an anti-SARS-COV2 IgM response, prior to IgG responses had lower titres of anti-beta-HCoV IgG antibodies. This indicated that pre-existing immunity to beta-HCoV was conducive to the generation of memory type responses to SARS-COV-2. Finally, we also found that pre-COVID-19-era sera and IVIG cross-reacted with SARS-CoV-2 antigens without neutralising SARS-CoV-2 infectivity in vitro. Put together, these results indicate that whilst pre-existing immunity to HCoV is responsible for recall-type IgG responses to SARS-CoV-2, it does not lead to cross-protection against COVID-19.
ObjectivesOur aims were to evaluate Systemic Lupus Erythematosus (SLE) disease activity and SARS-CoV-2 specific immune responses after BNT162b2 vaccination.MethodsIn this prospective study, disease activity and clinical assessments were recorded from the first dose of vaccine, until day 15 after the second dose in 126 SLE patients. SARS-CoV-2 antibody responses were measured against wild-type spike antigen while serum-neutralizing activity was assessed against the SARS-CoV-2 historical strain and variants of concerns (VOCs). Vaccine-specific T-cell responses were quantified by Interferon (IFN)-γ release assay after the second dose.ResultsBNT162b2 was well tolerated and no statistically significant variations of BILAG and SLEDAI scores were observed throughout the study in SLE patients with active and inactive disease at baseline. Mycophenolate Mofetil (MMF) and Methotrexate (MTX) treatments were associated with drastically reduced BNT162b2 antibody-response (β=-78; p=0.007, β=-122; p<0.001, respectively). Anti-spike antibody response was positively associated with baseline total IgG serum levels, naïve B cell frequencies (β=2; p=0.018, β=2.5; p=0.003) and SARS-CoV-2-specific T cell response (r=0.462; p=0.003). In responders, serum neutralization activity decreased against VOCs bearing the E484K mutation but remained detectable in a majority of patients.ConclusionMMF, MTX and poor baseline humoral immune status, particularly: low naïve B cell frequencies, are independently associated with impaired BNT162b2 mRNA antibody response, delineating SLE patients who might need adapted vaccine regimens and follow-up.KEY MESSAGESWhat is already known about this subject?BNT162b2 efficacy and safety has been described in studies mixing different RMDsWhat does this study add?No serious adverse effects, nor SLE flares have been documented after BNT162b2 in SLE patients.Not only MMF and MTX, but also a poor humoral immune status at baseline impair vaccine antibody responseAlbeit decreased, serum neutralizing activity against VOCs is conferred to vaccine-responders.How might this impact on clinical practice or future developments?These parameters could be helpful for physicians to delineate which patients should have antibody measurement after full BNT162b2 vaccination and should be proposed a third injection of BNT162b2 vaccine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.