The practical impact of analytical probes that transduce in the near-infrared (nIR) has been dampened by the lack of cost-effective and portable nIR fluorimeters. Herein, we demonstrate straightforward designs for an inexpensive microplate reader and a portable fluorimeter. These instruments require minimally complex machining and fabrication and operate with an open-source programming language (Python). Complete wiring diagrams, assembly diagrams, and scripts are provided. To demonstrate the utility of these two instruments, we performed high-throughput and field-side measurements of soil samples to evaluate the effect of soil management strategies on extracellular proteolytic, cellulolytic, and lignin-modifying activities. This was accomplished with fluorescent enzyme probes that utilized uniquely sensitive transducers exclusive to the nIR spectrum, single-walled carbon nanotubes. We also used the portable fluorimeter to evaluate spatial variations of proteolytic activity within individual field plots, while minimizing the effects of soil storage and handling. These demonstrations indicate the utility of these fluorimeters for translating analytical probes that operate in the nIR beyond the laboratory and into actual use.
Hydrolase co-therapies that degrade biofilm extracellular polymeric substances (EPS) allow for a better diffusion of antibiotics and more effective treatment; current methods for quantitatively measuring the enzymatic degradation of EPS are not amendable to high-throughput screening. Herein, we present biofilm EPS-functionalized single-walled carbon nanotube (SWCNT) probes for rapid screening of hydrolytic enzyme selectivity and activity on EPS. The extent of biofilm EPS degradation is quantified by monitoring the quenching of the SWCNT fluorescence. We used this platform to screen 16 hydrolases with varying bond breaking selectivity against a panel of wild-type Pseudomonas aeruginosa and mutants deficient or altered in one or more EPS. Next, we performed concentration-dependent studies of six enzymes on two common strains found in cystic fibrosis (CF) environments and, for each enzyme, extracted three first-order rate constants and their relative contributions by fitting a parallel, multi-site degradation model, with a good model fit (R 2 from 0.65 to 0.97). Reaction rates (turnover rates) are dependent on the enzyme concentration and range from 6.67 × 10–11 to 2.80 × 10–3 *s–1 per mg/mL of enzymes. Lastly, we confirmed findings from this new assay using an established crystal-violet staining assay for a subset of hydrolase panels. In summary, our work shows that this modular sensor is amendable to the high-throughput screening of EPS degradation, thereby improving the rate of discovery and development of novel hydrolases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.