A series of U(IV) complexes, ((R)ap)2U(THF)2 [R = tert-butyl (t-Bu) (1), adamantyl (Ad) (2), diisopropylphenyl (dipp) (3)], supported by the redox-active 4,6-di-tert-butyl-2-(R)amidophenolate ligand, have been synthesized by salt metathesis of 2 equiv of the alkali metal salt of the ligand, M2[(R)ap] [M = K (1 and 2), Na (3)], with UCl4. Exposure of these uranium complexes to 1 equiv of PhICl2 results in oxidative addition to uranium, forming the bis-(4,6-di-tert-butyl-2-(R)iminosemiquinone) ([(R)isq](1-)) uranium(IV) dichloride dimer, [((R)isq)2UCl]2(μ(2)-Cl)2 [R = t-Bu (4), Ad (5), dipp (6)]. The addition of iodine to 1 forms ((tBu)isq)2UI2(THF) (7), while the reactivity of I2 with 2 and 3 results in decomposition. Complexes 1-7 have been characterized by (1)H NMR and electronic absorption spectroscopies. X-ray crystallography was employed to elucidate structural parameters of 2, 3, 5, and 7.
Single-particle analysis of biosensors that use charge transfer as the means for analyte-dependent signaling with semiconductor nanoparticles, or quantum dots, was examined. Single-particle analysis of biosensors that use energy transfer show analyte-dependent switching of nanoparticle emission from off to on. The charge-transfer-based biosensors reported here show constant emission, where the analyte (maltose) increases the emission intensity. By monitoring the same nanoparticles under various conditions, a single charge-transfer-based biosensor construct (one maltose binding protein, one protein attachment position for the reductant, one type of nanoparticle) showed a dynamic range for analyte (maltose) detection spanning from 100 pM to 10 μM while the emission intensities increase from 25 to 175% at the single-particle level. Since these biosensors were immobilized, the correlation between the detected maltose concentration and the maltose-dependent emission intensity increase could be examined. Minimal correlation between maltose detection limits and emission increases was observed, suggesting a variety of reductant-nanoparticle surface interactions that control maltose-dependent emission intensity responses. Despite the heterogeneous responses, monitoring biosensor emission intensity over 5 min provided a quantifiable method to monitor maltose concentration. Immobilizing and tracking these biosensors with heterogeneous responses, however, expanded the analyte-dependent emission intensity and the analyte dynamic range obtained from a single construct. Given the wide dynamic range and constant emission of charge-transfer-based biosensors, applying these single molecule techniques could provide ultrasensitive, real-time detection of small molecules in living cells.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.