PurposeThe aim of this study is to quantify and describe the feasibility, clinical outcomes, and patient-reported outcomes of reduced planning target volume (PTV) margins for prostate cancer treatment using real-time, continuous, intrafraction monitoring with implanted radiation frequency transponder beacons.Methods and materialsFor this prospective, nonrandomized trial, the Calypso localization system was used for intrafraction target localization in 31 patients with a PTV margin reduced to 2 mm in all directions. A total of 1333 fractions were analyzed with respect to movement of the prostate, pauses and interruptions, and dosimetric data. Pre- and posttreatment quality-of-life scores were tracked at baseline, during treatment, and up to 24 months after treatment.ResultsThe mean time of daily treatment was 10 minutes, with 96.1% of all treatments falling within a 20-minute treatment window standard. On average, beacon motion exceeded 3 mm during active treatment only 1.76% of the time. The average length of treatment interruption was 34.2 seconds, with an average of 1 interruption every 3.39 fractions. The displacement or excursion of the prostate was the greatest in the superior or inferior dimension (0.11 mm and 0.09 mm, respectively) and anterior or posterior dimension (0.07 mm and 0.13 mm, respectively), followed by the left or right dimension (0.05 mm and 0.06 mm, respectively). At 6 months, patients demonstrated a smaller change in Expanded Prostate Cancer Index Composite scores than the ProtecT comparator group (decreased short-term morbidity). However, in the Bowel and Urinary domains at 12 and 24 months, there was no significant difference.ConclusionsOur data confirm and support that the use of Calypso tracking with intensity modulated radiation therapy reliably provides minimal disruption to daily treatments and overall time of treatment, with the PTV only moving outside of a 3-mm margin < 2% of the time. The use of a 3-mm PTV margin provides adequate dosimetric coverage while minimizing genitourinary and gastrointestinal toxicity.
OBJECTIVES: Most high-fidelity medical simulation is of limited duration, used for education and training, and rarely intended to study medical technology. U.S. caregivers working in prehospital, resource-limited settings may need to manage patients for extended periods (hours to days). This “prolonged casualty care” occurs during military, wilderness, humanitarian, disaster, and space medicine. We sought to develop a standardized simulation model that accurately reflects prolonged casualty care in order to study caregiver decision-making and performance, training requirements, and technology use in prolonged casualty care. DESIGN: Model development. SETTING: High-fidelity simulation laboratory. SUBJECTS: None. INTERVENTIONS: We interviewed subject matter experts to identify relevant prolonged casualty care medical challenges and selected two casualty types to further develop our model: a large thermal burn model and a severe hypoxia model. We met with a multidisciplinary group of experts in prolonged casualty care, nursing, and critical care to describe how these problems could evolve over time and how to contextualize the problems with a background story and clinical environment with expected resource availability. Following initial scenario drafting, we tested the models with expert clinicians. After multiple tests, we selected the hypoxia model for refinement and testing with inexperienced providers. We tested and refined this model until two research teams could proctor the scenario consistently despite subject performance variability. MEASUREMENTS AND MAIN RESULTS: We developed a 6–8-hour simulation model that represented a 14-hour scenario. This model of pneumonia evolved from presentation to severe hypoxia necessitating advanced interventions including airway, breathing, and shock management. The model included: context description, caregiver orientation scripts, hourly progressive physiology tracks corresponding to caregiver interventions, intervention/procedure-specific physiology tracks, intervention checklists, equipment lists, prestudy checklists, photographs of setups, procedure, telementor, and role player scripts, business rules, and data collection methods. CONCLUSIONS: This is the first standardized, high-fidelity simulation model of prolonged casualty care described in the literature. It may be used to assess caregiver performance and patient outcomes resulting from that performance during a complex, 14-hour prolonged casualty care scenario. Because it is standardized, the model may be used to compare differences in the impact of new technologies upon caregiver performance and simulated patient outcomes..
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.