Detection of large LRP by NIRS at non-stented sites in a target artery was associated with an increased risk of future MACCE. These findings support ongoing prospective studies to further evaluate the ability of NIRS to identify vulnerable patients.
In a high-volume center, the incidence of pericarditis, cardiac perforation, tamponade, death, and lead dislodgement was significantly higher with the MR-conditional Medtronic 5086 lead when compared to the previous generation Medtronic 5076 lead.
Objectives
This study was conducted to evaluate the association of geographic distance with robotic telestenting performance by comparing performance measures in transcontinental and regional pre‐clinical models of telestenting.
Background
Robotic telestenting, in which percutaneous coronary intervention (PCI) is performed on a remotely located patient, might improve PCI access, but has not been attempted over vast distances likely required to reach many underserved regions.
Methods
Telestenting performance was compared in regional (Boston to New York [206 miles]) and transcontinental (Boston to San Francisco [3,085 miles]) ex vivo models of telestenting, wherein a physician in Boston attempted robotic PCI on endovascular simulators in New York and San Francisco, respectively. PCI was attempted over both wired and fifth generation (5G)‐wireless networks. Outcome measures included procedural success, procedural time, and perceived latency.
Results
Procedural success was achieved in 20 consecutive target lesions in the regional model and in 16 consecutive target lesions in the transcontinental model. The transcontinental model had a greater latency than the regional model over both wired (121.5 ± 2.4 ms vs. 67.8 ± 0.9 ms; p < .001) and 5G‐wireless networks (162.5 ± 1.1 ms vs. 86.6 ± 0.6 ms; p < .001), but perceived latencies were graded “imperceptible” in all cases in both models. Transcontinental and regional models did not have significantly different procedural times over wired (4.1 ± 1.9 min vs. 9.0 ± 7.1 min; p = .051) or 5G‐wireless (3.0 ± 0.6 vs. 6.3 ± 1.2; p = .36) networks.
Conclusions
Transcontinental robotic manipulation of coronary devices is now possible and was not associated with adverse performance compared to robotic telestenting conducted regionally.
Background:
Consistent with the increasing prevalence of obesity in the general population, obesity has become more prevalent among patients undergoing cardiac catheterization. This study evaluated the association between patient body mass index (BMI) and physician radiation dose during coronary angiography.
Methods and Results:
Real-time radiation exposure data were collected during consecutive coronary angiography procedures. Patient radiation dose was estimated using dose area product. Physician radiation dose in each case was recorded by a dosimeter worn by the physician and is reported as the personal dose equivalent (H
p
10). Patient BMI was categorized as <25.0, 25.0 to 29.9, 30.0 to 34.9, 35.0 to 39.9, and ≥40. Among 1119 coronary angiography procedures, significant increases in dose area product and physician radiation dose were observed across increasing patient BMI categories (
P
<0.001). Compared with a BMI <25, a patient BMI ≥40 was associated with a 2.1-fold increase in patient radiation dose (dose area product, 91.8 [59.6–149.2] versus 44.5 [25.7–70.3] Gy×cm
2
;
P
<0.001) and a 7.0-fold increase in physician radiation dose (1.4 [0.2–7.1] versus 0.2 [0.0–2.9] μSv;
P
<0.001). By multiple regression analysis, patient BMI remained independently associated with physician radiation dose (dose increase, 5.2% per unit increase in BMI; 95% CI, 3.0%–7.5%;
P
<0.0001).
Conclusions:
Among coronary angiography procedures, increasing patient BMI was associated with a significant increase in physician radiation dose. Additional studies are needed to determine whether patient obesity might have adverse effects on physicians, in the form of increased radiation doses during coronary angiography.
The relatively simple approach of using accessory lead shields to protect staff members during cardiac catheterization was associated with a nearly two-thirds reduction in radiation exposure among nurses and technologists.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.