Hemostasis is a dynamic age-related process, which gradually evolves from fetal life throughout childhood until adulthood. Although at birth there is a hemostatic deficit of most coagulation factors, studies have shown that this “hemostatic immaturity” is functionally counterbalanced in healthy term or preterm newborns. This delicate hemostatic balance is, however, deranged in sick neonates, resulting in an enhanced risk of hemorrhage and/or thrombosis. In critically ill neonates, conventional coagulation tests do not seem to provide reliable information or indications regarding the functional status of platelets or fibrinolysis. In contrast, viscoelastic tests, namely thromboelastography/thromboelastometry (TEG/TEM) hold promise for rapid assessment of the whole hemostatic potential, allowing immediate intervention should this be required. However, neonatal data are limited due to lack of reference values, especially in premature neonates. In this narrative review, we provide some insights around current knowledge regarding TEG/TEM applications in healthy and sick newborns. Overall, the use of viscoelastic tests in diagnosis and management of coagulation disorders in neonates is definitely worth further exploration. Consideration should be made to include these tests in the routine laboratory investigation of neonates and specific transfusion algorithms should also be developed in order to avoid treatment pitfalls.
The aim of the study was to develop and validate a prediction model for hemorrhage in critically ill neonates which combines rotational thromboelastometry (ROTEM) parameters and clinical variables. This cohort study included 332 consecutive full-term and preterm critically ill neonates. We performed ROTEM and used the neonatal bleeding assessment tool (NeoBAT) to record bleeding events. We fitted double selection least absolute shrinkage and selection operator logit regression to build our prediction model. Bleeding within 24 hours of the ROTEM testing was the outcome variable, while patient characteristics, biochemical, hematological, and thromboelastometry parameters were the candidate predictors of bleeding. We used both cross-validation and bootstrap as internal validation techniques. Then, we built a prognostic index of bleeding by converting the coefficients from the final multivariable model of relevant prognostic variables into a risk score. A receiver operating characteristic analysis was used to calculate the area under curve (AUC) of our prediction index. EXTEM A10 and LI60, platelet counts, and creatinine levels were identified as the most robust predictors of bleeding and included them into a Neonatal Bleeding Risk (NeoBRis) index. The NeoBRis index demonstrated excellent model performance with an AUC of 0.908 (95% confidence interval [CI]: 0.870–0.946). Calibration plot displayed optimal calibration and discrimination of the index, while bootstrap resampling ensured internal validity by showing an AUC of 0.907 (95% CI: 0.868–0.947). We developed and internally validated an easy-to-apply prediction model of hemorrhage in critically ill neonates. After external validation, this model will enable clinicians to quantify the 24-hour bleeding risk.
Background and Objective: Peripherally inserted central catheters (PICC) and umbilical venous catheters (UVC) are frequently used for vascular access in neonatal intensive care units (NICUs). While there is a significant need for these devices for critically ill neonates, there are many complications associated with their use. We aimed at investigating the incidence of UVC and PICC complications in very low birth weight (VLBW) infants. Materials and Methods: This is an observational study performed with neonates of the tertiary General Hospital of Piraeus, Greece, during an 18 month-period. Seventy-one neonates were recruited and divided into two groups: 34 neonates with PICC and 37 neonates with UVC. We recorded: Catheter dwell time, the causes of catheter removal, other complications, infections, and catheter tip colonization rates. Results: No significant statistical differences were noticed between the 2 study groups with regards to demographic characteristics, causes for catheter removal, catheter indwelling time or the incidence of nosocomial infection. Eleven UVC tips and no PICC tips were proved colonized (p = 0.001) following catheter removal. Conclusions: The incidence of complications associated with the use of UVCs and PICCs in VLBW infants did not significantly differ in our study. Their use seems to be equally safe. Further studies, with larger samples, are necessary to confirm our results.
Perinatal hypoxia is associated with an increased risk of coagulation disorders by enhancing the consumption of platelets and some clotting factors due to the associated severe hypoxemia, acidemia, and compromised oxygen and blood supply to the neonatal liver and bone marrow. Thromboelastometry (TEM), which estimates the dynamics of blood coagulation, may represent an attractive tool for studying the coagulation status of these neonates. We aimed at assessing the hemostatic profile of neonates with perinatal hypoxia using the standard extrinsically activated TEM (ex-TEM) assay. In total, 164 hospitalized neonates with perinatal asphyxia and/or fetal distress comprised the study subjects, and 273 healthy neonates served as controls. Ex-TEM assay was performed, SNAPPE (Score for Neonatal Acute Physiology Perinatal Extension) was calculated, and clinical findings and laboratory results were recorded in all study subjects. Hypoxic neonates expressed a prolonged clotting time (CT) and clot formation time (CFT) and reduced amplitude at 10 minutes (A10), α-angle, and maximum clot firmness compared with healthy neonates. Furthermore, asphyxiated neonates had a significantly prolonged CT and CFT and reduced A10 and α-angle compared with neonates with fetal distress. Hypoxic neonates demonstrate a hypocoagulable ex-TEM profile relative to healthy neonates, indicating a potential role of TEM in the early detection of coagulation derangement in perinatal hypoxia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.