Telecentric beam scanning using f-
θ
lenses offers nearly uniform spot size, linear beam displacement, and normal incidence angle over a planar surface. These unique properties allow for the minimization of imaging distortion over a wide field-of-view. In this article, we present a numerical method for designing custom f-
θ
lenses in the THz regime. We fabricated three lenses made from different commonly used polymer materials in the THz optics. We demonstrated their optical performance metrics compared to a conventional plano-convex lens over the broadband 0.3 THz–1 THz range. We find that the f-
θ
lens designed using the optical properties of high-density polyethylene achieved superior performance by maintaining a constant phase over a wide field of view of about 34°. We demonstrate this isophase property by measuring a constant time of arrival of the THz time-domain pulses over a reference mirror with a standard deviation of ∼19 fs, in excellent agreement with simulation predictions. This work will pave the way for the design and implementation of highly precise and fast telecentric imaging systems in the THz frequencies.
We apply terahertz (THz) time-domain spectroscopy for monitoring the curing process of three different light-curing dental composites. Exact knowledge of the sample thickness is required for a precise determination of the THz dielectric parameters, as the materials exhibit shrinkage when they are cured. We find very small but significant changes of the THz refractive index and absorption coefficient during stepwise light exposure. The changes in the refractive index are correlated with changes in the density of the materials. Furthermore, the refractive index and the sample thickness are found to give the most reliable result for monitoring the curing process of the dental composites.
In this work, we develop a pulsed terahertz imaging system in reflection geometry, where due to scanning of the terahertz beam neither the sample nor the emitter and detector have to be moved. We use a two mirror galvanoscanner for deflecting the beam, in combination with a single rotationally symmetric focusing lens. In order to efficiently image planar structures, we develop an advanced scanning routine that resolves all bending effects of the imaging plane already during measurement. Thus, the measurement time is reduced, and efficient imaging of surfaces and interfaces becomes possible. We demonstrate the potential of this method in particular for a plastic-metal composite sample, for which non-destructive evaluation of an interface is performed.
Objectives: High counts of averaged interictal epileptiform discharges (IEDs) are key components of accurate interictal electric source imaging (ESI) in patients with focal epilepsy. Automated detections may be time-efficient, but they need to identify the correct IED types. Thus we compared semiautomated and automated detection of IED types in long-term video-EEG (electroencephalography) monitoring (LTM) using an extended scalp EEG array and short-term highdensity EEG (hdEEG) with visual detection of IED types and the seizure-onset zone (SOZ).
Methods:We prospectively recruited consecutive patients from four epilepsy centers who underwent both LTM with 40-electrode scalp EEG and short-term hdEEG with 256 electrodes. Only patients with a single circumscribed SOZ in LTM were included. In LTM and hdEEG, IED types were identified visually, semiautomatically and automatically. Concordances of semiautomated and automated detections in LTM and hdEEG, as well as visual detections in hdEEG, were compared against visually detected IED types and the SOZ in LTM.Results: Fifty-two of 62 patients with LTM and hdEEG were included. The most frequent IED types per patient, detected semiautomatically and automatically in LTM and visually in hdEEG, were significantly concordant with the most frequently visually identified IED type in LTM and the SOZ. Semiautomated and automated detections of IED types in hdEEG were significantly concordant with visually identified IED types in LTM, only when IED types with more than 50 detected single IEDs were selected. The threshold of 50 detected IED in hdEEG was reached in half of the patients. For all IED types per patient, agreement between visual and semiautomated detections in LTM was high.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.