IntroductionSeveral studies have shown that goal-directed hemodynamic and fluid optimization may result in improved outcome. However, the methods used were either invasive or had other limitations. The aim of this study was to perform intraoperative goal-directed therapy with a minimally invasive, easy to use device (FloTrac/Vigileo), and to evaluate possible improvements in patient outcome determined by the duration of hospital stay and the incidence of complications compared to a standard management protocol.MethodsIn this randomized, controlled trial 60 high-risk patients scheduled for major abdominal surgery were included. Patients were allocated into either an enhanced hemodynamic monitoring group using a cardiac index based intraoperative optimization protocol (FloTrac/Vigileo device, GDT-group, n = 30) or a standard management group (Control-group, n = 30), based on standard monitoring data.ResultsThe median duration of hospital stay was significantly reduced in the GDT-group with 15 (12 - 17.75) days versus 19 (14 - 23.5) days (P = 0.006) and fewer patients developed complications than in the Control-group [6 patients (20%) versus 15 patients (50%), P = 0.03]. The total number of complications was reduced in the GDT-group (17 versus 49 complications, P = 0.001).ConclusionsIn high-risk patients undergoing major abdominal surgery, implementation of an intraoperative goal-directed hemodynamic optimization protocol using the FloTrac/Vigileo device was associated with a reduced length of hospital stay and a lower incidence of complications compared to a standard management protocol.Trial RegistrationClinical trial registration information: Unique identifier: NCT00549419
In patients undergoing major abdominal surgery, a colloid-based (with hydroxyethyl starch [HES] 130/0.4) and a crystalloid-based (with lactated Ringer's solution [RL]) volume replacement regimen was compared regarding tissue oxygen tension (ptiO(2)) measured continuously by microsensoric implantable catheters. The ptiO(2) increased in the HES-treated (+59%) but decreased in the RL-treated (-23%) patients. Improved microcirculation may be the mechanism for the better ptiO(2) in the HES group.
In cardiac surgery patients, CO measured by a new semi-invasive arterial pressure waveform analysis device showed only moderate agreement with intermittent pulmonary artery thermodilution measurement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.