Background Low and mid station vacuum assisted deliveries (VAD) are delicate manual procedures that entail a high degree of subjectivity from the operator and are associated with adverse neonatal outcome. Little has been done to improve the procedure, including the technical development, traction force and the possibility of objective documentation. We aimed to explore if a digital handle with instant haptic feedback on traction force would reduce the neonatal risk during low or mid station VAD. Methods A two centre, randomised superiority trial at Karolinska University Hospital, Sweden, 2016–2018. Cases were randomised bedside to either a conventional or a digital handle attached to a Bird metal cup (50 mm, 80 kPa). The digital handle measured applied force including an instant notification by vibration when high levels of traction force were predicted according to a predefined algorithm. Primary outcome was a composite of hypoxic ischaemic encephalopathy, intracranial haemorrhage, seizures, death and/or subgaleal hematoma. Three hundred eighty low and mid VAD in each group were estimated to decrease primary outcome from six to 2 %. Results After 2 years, an interim analyse was undertaken. Meeting the inclusion criteria, 567 vacuum extractions were randomized to the use of a digital handle (n = 296) or a conventional handle (n = 271). Primary outcome did not differ between the two groups: (2.7% digital handle vs 2.6% conventional handle). The incidence of primary outcome differed significantly between the two delivery wards (4% vs 0.9%, p < 0.05). A recalculation of power revealed that 800 cases would be needed in each group to show a decrease in primary outcome from three to 1 %. This was not feasible, and the study therefore closed. Conclusions The incidence of primary outcome was lower than estimated and the study was underpowered. However, the difference between the two delivery wards might reflect varying degree of experience of the technical equipment. An objective documentation of the extraction procedure is an attractive alternative in respect to safety and clinical training. To demonstrate improved safety, a multicentre study is required to reach an adequate cohort. This was beyond the scope of the study. Trial registration ClinicalTrials.gov NCT03071783, March 1, 2017, retrospectively registered.
Introduction:During the second stage of labor, vacuum-assisted delivery is an alternative to forceps delivery and emergency cesarean section. Extensive research concerning perinatal outcomes has indicated that the risk of complications, although rare, is higher than with a spontaneous vaginal delivery. An important factor related to perinatal outcomes is the traction force applied. Our research group previously developed a digital extraction handle, the Vacuum Intelligent Handle-3 (VIH3), that measures and records traction force. The objective of this study was to compare traction force profiles in children with and without severe perinatal outcomes delivered with the digital handle. A secondary aim was to establish a safe force limit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.