ABSTRACT. Background. Jaundice in near-term and term newborns is a frequent diagnosis that may prompt hospital readmission in the first postnatal week. Hyperbilirubinemia, when excessive, can lead to potentially irreversible bilirubin-induced neurotoxicity. Predischarge risk assessment (at 24 -72 hours of age) for subsequent excessive hyperbilirubinemia is feasible by a laboratory-based assay of total serum bilirubin (TSB).Hypothesis. Noninvasive, transcutaneous, point-ofcare measurement of transcutaneous bilirubin (TcB) predischarge by multiwavelength spectral analysis, using a portable BiliCheck device (SpectRx Inc, Norcross, GA), is clinically equivalent to measurement of TSB in a diverse, multiracial term and near-term newborn population and predictive of subsequent hyperbilirubinemia.Methodology. We evaluated a hand-held device that uses multiwavelength spectral reflectance analysis to measure TcB (BiliCheck). The study population (490 term and near-term newborns) was racially diverse (59.1% white, 29.5% black, 3.46% Hispanic, 4.48% Asian, and 3.46% other) and was evaluated at 2 separate institutions using multiple (11) devices. The postnatal age ranged from 12 to 98 hours and the ranges of birth weights and gestational ages were 2000 to 5665 g and 35 to 42 weeks, respectively. All transcutaneous evaluations were performed contemporaneously and paired with a heelstick TSB measurement. All TSB assays were performed by high performance liquid chromatography, as well as by diazo dichlorophenyldiazonium tetrafluoroborate techniques.Results. TSB values ranged from .2 to 18.2 mg/dL (mean ؎ standard deviation: 7.65 ؎ 3.35 mg/dL). The overall correlation of TSB (by high performance liquid chromatography technique) to TcB (by BiliCheck devices) was linear and statistically significant (r ؍ .91; r 2 ؍ .83; TcB ؍ .84; TSB ؍ ؉.75; standard error of regression line ؍ 1.38; P < .001; n ؍ 490 infants; 1788 samples). Similar regression statistics were evident in subset populations categorized by race (white: r ؍ .91 [n ؍ 289 infants]; black: r ؍ .91 [n ؍ 145 infants]) as well as by gestation (term: r ؍ .91 [n ؍ 1625 samples]; near-term: r ؍ .89 [n ؍ 163 samples]). Intradevice precision was determined to be .59 mg/dL (2-3 measurements per infant with 1 device; n ؍ 210 infants; 510 samples in a separate subset). Interdevice evaluation of 11 devices determined the precision to be .68 mg/dL (2-4 devices used for measurements per patient).In 23 of 419 of the study population infants who were in the 24-to 72-hour age range, the predischarge TSB values designated them to be at high risk for subsequent excessive hyperbilirubinemia (above the 95th percentile track on the hour-specific bilirubin nomogram). For these infants, the paired BiliCheck TcB values were all above the 75th percentile track (negative predictive value ؍ 100%; positive predictive value ؍ 32.86%; sensitivity ؍ 100%; specificity ؍ 88.1%; likelihood ratio ؍ 8.43).Conclusions. Our data demonstrate the accuracy and reproducibil...
Despite improvements in the care of preterm infants, intraventricular hemorrhage (IVH) and posthemorrhagic hydrocephalus (PHH) continue to be frequent occurrences in this patient population. Shunt procedures in these children are frequently complicated by obstruction and/or infection. As the hydrocephalus is usually caused by an obliterative arachnoiditis due to contact of the blood with the basilar meninges, it was postulated that infusion of urokinase into the ventricles of infants who have sustained an IVH would clear the blood, mitigate the arachnoiditis, and prevent the progression of PHH. Accordingly, 18 preterm infants who had sustained IVH and subsequently developed PHH were treated with intraventricular urokinase instilled via a surgically implanted subcutaneous reservoir. There were no complications associated with the urokinase. Infants were divided into two dosage groups: low dose (110,000–140,000 IU total) and high dose (280,000 IU total). One infant in the low-dose group died at 1 month of life of respiratory complications. In the low-dose group, 3 of 8 (37%) infants required shunt placement; in the high-dose group, all 9 required shunt placement. For the total group, the shunt rate was 71 %. This compares to a historical control group shunt rate of 92%. While the difference between the treatment group as a whole and control group approaches, but does not reach, statistical significance (p = 0.068), there was a significant reduction in the shunt rate when the low-dose group was considered separately (p < 0.002). For those infants that required shunt placement, there were fewer shunt revisions performed in the treatment group than in the control group during the first 24 months following shunt placement: 0.67 versus 1.5 shunt revisions/shunted child. Initial experience with intraventricular urokinase following IVH and PHH in preterm infants suggests a beneficial effect in reducing the shunt revision rate in both high- and low-dose groups. Reduction in shunt placement rate is seen only in the low-dose group.
Background: There is a rapidly growing literature available on right hemicolectomy comparing the short- and long-term outcomes of robotic right colectomy (RRC) to that of laparoscopic right colectomy (LRC). The aim of this meta-analysis is to revise current comparative literature systematically. Methods: A systematic review of comparative studies published between 2000 to 2021 in PubMed, Scopus and Embase was performed. The primary endpoint was postoperative morbidity, mortality and long-term oncological results. Secondary endpoints consist of blood loss, conversion rates, complications, time to first flatus, hospital stay and incisional hernia rate. Results: 25 of 322 studies were considered for data extraction. A total of 16,099 individual patients who underwent RRC (n = 1842) or LRC (n = 14,257) between 2002 and 2020 were identified. Operative time was significantly shorter in the LRC group (LRC 165.31 min ± 43.08 vs. RRC 207.38 min ± 189.13, MD: −42.01 (95% CI: −51.06−32.96), p < 0.001). Blood loss was significantly lower in the RRC group (LRC 63.57 ± 35.21 vs. RRC 53.62 ± 34.02, MD: 10.03 (95% CI: 1.61–18.45), p = 0.02) as well as conversion rate (LRC 1155/11,629 vs. RRC 94/1534, OR: 1.65 (1.28–2.13), p < 0.001) and hospital stay (LRC 6.15 ± 31.77 vs. RRC 5.31 ± 1.65, MD: 0.84 (95% CI: 0.29–1.38), p = 0.003). Oncological long-term results did not differ between both groups. Conclusion: The advantages of robotic colorectal procedures were clearly demonstrated. RRC can be regarded as safe and feasible. Most of the included studies were retrospective with a limited level of evidence. Further randomized trials would be suitable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.