Visible light optical coherence tomography (VIS-OCT) is an emerging ophthalmic imaging method uniquely featured by ultrahigh depth resolution, retinal microvascular oximetry, and distinct scattering contrast in the visible spectral range. However, the clinical utility of VIS-OCT is impeded by the fundamental trade-off between the imaging depth range and axial resolution, determined by the spectral resolution and bandwidth respectively. While the full potential of VIS-OCT is leveraged by a broad bandwidth, the imaging depth is inversely sacrificed. The effective depth range is further limited by the wavelength-dependent roll-off that the signal-to-noise ratio (SNR) reduces in the deeper imaging range, more so in shorter wavelength. To address this trade-off, we developed a second-generation dual-channel VIS-OCT system including the first linear-in-k VIS-OCT spectrometer, reference pathlength modulation, and per A-line noise cancellation. All combined, we have achieved 7.2dB roll-off over the full 1.74 mm depth range (water) with shot-noise limited performance. The system uniquely enables >60° wide-field imaging over large retinal curvature at peripheral retina and optic nerve head, as well as high-definition imaging at ultrahigh 1.3 um depth resolution (water). The dual-channel design includes a conventional near infrared (NIR) channel, compatible with Doppler OCT and OCT angiography (OCTA). The comprehensive structure-function measurement by 2nd-Gen VIS-OCT system is a significant advance towards broader adaptation of VIS-OCT in clinical applications.
Visible light optical coherence tomography (VIS-OCT) is an emerging ophthalmic imaging method featuring ultrahigh depth resolution, retinal microvascular oximetry, and distinct scattering contrast in the visible spectral range. The clinical utility of VIS-OCT is hampered by the fundamental trade-off between the imaging depth range and axial resolution, which are determined by the spectral resolution and bandwidth, respectively. While the full potential of VIS-OCT is leveraged by a broad bandwidth, the imaging depth is inversely sacrificed. The effective depth range is further limited, especially in the shorter wavelengths, by the spectrally dependent roll-off of the signal-to-noise ratio (SNR). To address this trade-off, we developed a second-generation (2nd Gen) dual-channel VIS-OCT system with three major advancements including the first linear-in-K VIS-OCT spectrometer to decrease the roll-off, reference pathlength modulation to expand the imaging depth range, and per-A-line noise cancellation to remove excess noise, Due to these unique designs. this system achieves 7.2 dB roll-off over the full 1.74 mm depth range (water) with shot-noise limited performance. The system uniquely enables > 60° wide-field imaging which would allow simultaneous imaging of the peripheral retina and optic nerve head, as well as ultrahigh 1.3 µm depth resolution (water). Benefiting from the additional near-infrared (NIR) channel of the dual-channel design, this system was compatible with Doppler OC T and OCT angiography (OCTA). The comprehensive structure-function measurements enabled by this second-generation dual-channel VIS-OCT system is a significant advance towards adoption of VIS-OCT in clinical applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.