As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120,000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues from design and specifications to integration and evaluation. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.
Abstract-The level of hearing rehabilitation enjoyed by cochlear implant (CI) recipients has increased dramatically since the introduction of these devices. This improvement is the result of continual development of these systems and the inclusion of subjects with less severe auditory pathology. Developments include advanced signal processing, higher stimulation rates, greater numbers of channels, and more efficient electrode arrays that are less likely to produce insertion damage. New directions in the application of CIs, particularly in combined acoustic and electrical stimulation, and increasing performance expectations will place greater demands on future electrode arrays. Specifically, the next generation of arrays must be reliably inserted without damage, must maintain residual acoustic function, and may need to be inserted more deeply. In this study, we measured the mechanical properties of eight clinical and prototype human CI electrode arrays and evaluated insertion trauma and insertion depth in 79 implanted cadaver temporal bones. We found that the size and shape of the array directly affect the incidence of observed trauma. Further, arrays with greater stiffness in the plane perpendicular to the plane of the cochlear spiral are less likely to cause severe trauma than arrays with similar vertical and horizontal stiffness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.