BackgroundHydroxyapatite (HA) is the main inorganic component of bone, and HA coating is widely used on acetabular cups in hip arthroplasty. It has been suggested that this surface finish improves cup survival.MethodsAll patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2007 with an uncemented acetabular implant that was available either with or without HA coating were identified. 8,043 total hip arthroplasties (THAs) with the most common cup types (Harris-Galante, Romanus, and Trilogy) were investigated. A Cox regression model including type of coating, age, sex, primary diagnosis, cup type, and type of stem fixation was used to calculate adjusted risk ratios (RRs) for the risk of revision.ResultsHA coating was a risk factor for cup revision due to aseptic loosening (adjusted RR 1.7; 95% CI: 1.3–2). Age at primary arthroplasty of < 50 years, a diagnosis of pediatric hip disease, the use of a cemented stem, and the Romanus and Harris-Galante cup types were also associated with statistically significantly increased risk of cup revision due to aseptic loosening.InterpretationOur findings question the routine use of HA-coated cups in primary total hip arthroplasty. With some designs, this practice may even increase the risk of loosening—resulting in revision surgery.
Background and purposeIt is still being debated whether HA coating of uncemented stems used in total hip arthroplasty (THA) improves implant survival. We therefore investigated different uncemented stem brands, with and without HA coating, regarding early and long-term survival.Patients and methodsWe identified 152,410 THA procedures using uncemented stems that were performed between 1995 and 2011 and registered in the Nordic Arthroplasty Register Association (NARA) database. We excluded 19,446 procedures that used stem brands less than 500 times in each country, procedures performed due to diagnoses other than osteoarthritis or pediatric hip disease, and procedures with missing information on the type of coating. 22 stem brands remained (which were used in 116,069 procedures) for analysis of revision of any component. 79,192 procedures from Denmark, Norway, and Sweden were analyzed for the endpoint stem revision. Unadjusted survival rates were calculated according to Kaplan-Meier, and Cox proportional hazards models were fitted in order to calculate hazard ratios (HRs) for the risk of revision with 95% confidence intervals (CIs).ResultsUnadjusted 10-year survival with the endpoint revision of any component for any reason was 92.1% (CI: 91.8–92.4). Unadjusted 10-year survival with the endpoint stem revision due to aseptic loosening varied between the stem brands investigated and ranged from 96.7% (CI: 94.4–99.0) to 99.9% (CI: 99.6–100). Of the stem brands with the best survival, stems with and without HA coating were found. The presence of HA coating was not associated with statistically significant effects on the adjusted risk of stem revision due to aseptic loosening, with an HR of 0.8 (CI: 0.5–1.3; p = 0.4). The adjusted risk of revision due to infection was similar in the groups of THAs using HA-coated and non-HA-coated stems, with an HR of 0.9 (CI: 0.8–1.1; p = 0.6) for the presence of HA coating. The commonly used Bimetric stem (n = 25,329) was available both with and without HA coating, and the adjusted risk of stem revision due to aseptic loosening was similar for the 2 variants, with an HR of 0.9 (CI: 0.5–1.4; p = 0.5) for the HA-coated Bimetric stem.InterpretationUncemented HA-coated stems had similar results to those of uncemented stems with porous coating or rough sand-blasted stems. The use of HA coating on stems available both with and without this surface treatment had no clinically relevant effect on their outcome, and we thus question whether HA coating adds any value to well-functioning stem designs.
Background and purposeHydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA coating (Bi-Metric).Patients and methodsThe stem had been used in 4,772 total hip arthroplasties (THAs) in 4,169 patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2009. 59% of the stems investigated were coated with HA and 41% were uncoated. Kaplan-Meier survival analysis and a Cox regression model with adjustment for age, sex, primary diagnosis, and the type of cup fixation were used to calculate survival rates and adjusted risk ratios (RRs) of the risk of revision for various reasons.ResultsThe 10-year survival rates of the HA-coated version and the uncoated version were about equal when we used revision for any reason as the endpoint: 98% (95% CI: 98–99) and 98% (CI: 97–99), respectively. A Cox regression model adjusting for the covariates mentioned above showed that the presence of HA coating did not have any influence on the risk of stem revision for any reason (RR = 1.0, 95% CI: 0.6–1.6) or due to aseptic loosening (RR = 0.5, CI: 0.2–1.5). There was no effect of HA coating on the risk of stem revision due to infection, dislocation, or fracture.InterpretationThe uncemented Bi-Metric stem showed excellent 10-year survival. Our findings do not support the use of HA coating on this stem to enhance implant survival.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.