Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 microm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm(-1) and noise of +/-35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.
Micro-CT has become a powerful tool for small animal research, having the ability to obtain high-resolution in vivo and ex vivo images for analyzing bone mineral content, organ vasculature, and bone microarchitecture extraction. The use of exogenous contrast agents further extends the use of micro-CT techniques, but despite advancements in contrast agents, single-energy micro-CT is still limited in cases where two different materials share similar grey-scale intensity values. This study specifically addresses the development of multiple-energy cone-beam micro-CT, for applications where bone must be separated from blood vessels filled with a Pb-based contrast material (Microfil) in ex vivo studies of rodents and tissue specimens. The authors report the implementation of dual- and triple-energy CT algorithms for material-specific imaging using postreconstruction decomposition of micro-CT data; the algorithms were implemented on a volumetric cone-beam micro-CT scanner (GE Locus Ultra). For the dual-energy approach, extrinsic filtration was applied to the x-ray beam to produce spectra with different proportions of x rays above the K edge of Pb. The optimum x-ray tube energies (140 kVp filtered with 1.45 mm Cu and 96 kVp filtered with 0.3 mm Pb) that maximize the contrast between bone and Microfil were determined through numerical simulation. For the triple-energy decomposition, an additional low-energy spectrum (70 kVp, no added filtration) was used. The accuracy of decomposition was evaluated through simulations and experimental verification of a phantom containing a cortical bone simulating material (SB3), Microfil, and acrylic. Using simulations and phantom experiments, an accuracy greater than 95% was achieved in decompositions of bone and Microfil (for noise levels lower than 11 HU), while soft tissue was separated with accuracy better than 99%. The triple-energy technique demonstrated a slightly higher, but not significantly different, decomposition accuracy than the dual-energy technique for the same achieved noise level in the micro-CT images acquired at the multiple energies. The dual-energy technique was applied to the decomposition of an ex vivo rat specimen perfused with Microfil; successful decomposition of the bone and Microfil was achieved, enabling the visualization and characterization of the vasculature both in areas where the vessels traverse soft tissue and when they are surrounded by bone. In comparison, in single energy micro-CT, vessels surrounded by bone could not be distinguished from the cortical bone, based on grey-scale intensity alone. This work represents the first postreconstruction application of material-specific decomposition that directly takes advantage of the K edge characteristics of a contrast material injected into an animal specimen; the application of the technique resulted in automatic, accurate segmentation of 3D micro-CT images into bone, vessel, and tissue components. The algorithm uses only reconstructed images, rather than projection data, and is calibrated by an operat...
The P2X7 receptor is an ATP-gated cation channel expressed by a number of cell types. We have shown previously that disruption of P2X7 receptor function results in downregulation of osteogenic markers and upregulation of adipogenic markers in calvarial cell cultures. In the present study, we assessed whether loss of P2X7 receptor function results in changes to adipocyte distribution and lipid accumulation in vivo. Male P2X7 loss-of-function (KO) mice exhibited significantly greater body weight and epididymal fat pad mass than wild-type (WT) mice at 9 months of age. Fat pad adipocytes did not differ in size, consistent with adipocyte hyperplasia rather than hypertrophy. Histological examination revealed ectopic lipid accumulation in the form of adipocytes and/or lipid droplets in several non-adipose tissues of older male KO mice (9-12 months of age). Ectopic lipid was observed in kidney, extraorbital lacrimal gland and pancreas, but not in liver, heart or skeletal muscle. Specifically, lacrimal gland and pancreas from 12-month-old male KO mice had greater numbers of adipocytes in perivascular, periductal and acinar regions. As well, lipid droplets accumulated in the renal tubular epithelium and lacrimal acinar cells. Blood plasma analyses revealed diminished total cholesterol levels in 9-and 12-month-old male KO mice compared with WT controls. Interestingly, no differences were observed in female mice. Moreover, there were no significant differences in food consumption between male KO and WT mice. Taken together, these data establish novel in vivo roles for the P2X7 receptor in regulating adipogenesis and lipid metabolism in an age-and sex-dependent manner.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.