ObjectiveThe purpose of this in vitro study was to examine the effects of fluoridated, casein phosphopeptide.amorphous calcium phosphate complex (CPP-ACP)-containing, and functionalized β-tricalcium phosphate (fTCP)-containing toothpastes on remineralization of white spot lesions (WSLs) by using Quantitative light-induced fluorescence (QLF-D) Biluminator™ 2.MethodsForty-eight premolars, extracted for orthodontic reasons from 12 patients, with artificially induced WSLs were randomly and equally assigned to four treatment groups: fluoride (1,000 ppm), CPP-ACP, fTCP (with sodium fluoride), and control (deionized water) groups. Specimens were treated twice daily for 2 weeks and stored in saliva solution (1:1 mixture of artificial and human stimulated saliva) otherwise. QLF-D Biluminator™ 2 was used to measure changes in fluorescence, indicating alterations in the mineral contents of the WSLs, immediately before and after the 2 weeks of treatment.ResultsFluorescence greatly increased in the fTCP and CPP-ACP groups compared with the fluoride and control groups, which did not show significant differences.ConclusionsfTCP- and CPP-ACP-containing toothpastes seem to be more effective in reducing WSLs than 1,000-ppm fluoride-containing toothpastes.
Background: ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing.Methods: In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol.Results: The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions ( < 2+ reaction grade), extra serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤ 1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods.Conclusions: ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤ 1+ reaction grade do.
BackgroundNucleophosmin gene (NPM1) mutation may be a good molecular marker for assessing the clinical status and predicting the outcomes in AML patients. We evaluated the applicability of NPM1 type A mutation (NPM1-mutA) quantitation for this purpose.MethodsTwenty-seven AML patients with normal karyotype but bearing the mutated NPM1 were enrolled in the study, and real-time quantitative PCR of NPM1-mutA was performed on 93 bone marrow (BM) samples (27 samples at diagnosis and 56 at follow-up). The NPM1-mutA allele burdens (represented as the NPM1-mutA/Abelson gene (ABL) ratio) at diagnosis and at follow-up were compared.ResultsThe median NPM1-mutA/ABL ratio was 1.3287 at diagnosis and 0.092 at 28 days after chemotherapy, corresponding to a median log10 reduction of 1.7061. Significant correlations were observed between BM blast counts and NPM1-mutA quantitation results measured at diagnosis (γ=0.5885, P=0.0012) and after chemotherapy (γ=0.5106, P=0.0065). Total 16 patients achieved morphologic complete remission at 28 days after chemotherapy, and 14 (87.5%) patients showed a >3 log10 reduction of the NPM1-mutA/ABL ratio. The NPM1-mutA allele was detected in each of five patients who had relapsed, giving a median increase of 0.91-fold of the NPM1-mutA/ABL ratio at relapse over that at diagnosis.ConclusionsThe NPM1-mutA quantitation results corresponded to BM assessment results with high stability at relapse, and could predict patient outcomes. Quantitation of the NPM1-mutA burden at follow-up would be useful in the management of AML patients harboring this gene mutation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.