A histamine piezoelectric (acoustic) sensor using a molecularly imprinted polymer (MIP) film has been devised and tested. The sensor comprises an electrodeposited MIP film as the recognition element and a 10 MHz AT-cut shear-thickness-mode bulk-acoustic-wave quartz crystal resonator with Pt film electrodes as the signal transducer. Preparation of the sensing film involved two consecutive electrochemical polymerizations, performed under cyclic voltammetric conditions, with the use of a supporting electrolyte of 0.1 M tetra-n-butylammonium perchlorate in acetonitrile. First, a poly(bithiophene) barrier film was deposited by electropolymerization on the Pt/quartz resonator to prevent histamine electro-oxidation and avoid possible contamination of the Pt electrode surface. Next, the histamine-templated MIP film was deposited by electropolymerization on top of this barrier film. For that purpose, two functional monomers of bis(bithiophene) derivatives, i.e., one bearing the 18-crown-6 and the other dioxoborinane substituent, were copolymerized in the presence of the histamine template. The consecutive growth of both these overlaid films was monitored with an electrochemical quartz crystal microbalance (EQCM). Subsequently, the histamine was extracted from MIP with 0.01 M NaOH for 12 h. The UV-vis and X-ray photoelectron spectroscopic measurements confirmed the completeness of the removal of the histamine template from the MIP film. The analytical performance of the chemosensor was assessed under flow injection analysis (FIA) conditions using the carrier 0.5 M HEPES buffer (pH = 7.5) solution and the piezoelectric microgravimetry detection at QCM. The negative peaks of resonant frequency linearly decreased with the increase of the histamine concentration in the range 10-100 mM for 150 microL/min flow rate, and 100 microL volume of the injected sample. The sensitivity of the chemosensor (0.33 Hz/mM) was more than twice as that of the chemosensor without the poly(bithiophene) barrier film (0.15 Hz/mM). The chemosensor performance was superior for selective histamine recognition if the poly(bithiophene) barrier film thickness exceeded 200 nm. The chemosensor discriminated histamine from functionally or structurally similar compounds, such as dopamine, tryptamine, and imidazole. Stability constants of the affinity complexes of MIP and analyte or the interfering agent were determined from kinetic studies. For the MIP-histamine complex, the stability constant thus evaluated was equal to 57.0 M(-1) being much higher than those for the MIP-tryptamine and MIP-dopamine complexes determined to be 10.7, and 6.4 M(-1), respectively. The concentration limit of detection was as low as 5 nM histamine if the carrier solution flow rate was as low as 35 microL/min and the injection sample volume as large as 1 mL.
In principle, molecularly imprinted polymer science and technology provides a means for ready access to nano-structured polymeric materials of predetermined selectivity. The versatility of the technique has brought it to the attention of many working with the development of nanomaterials with biological or biomimetic properties for use as therapeutics or in medical devices. Nonetheless, the further evolution of the field necessitates the development of robust predictive tools capable of handling the complexity of molecular imprinting systems. The rapid growth in computer power and software over the past decade has opened new possibilities for simulating aspects of the complex molecular imprinting process. We present here a survey of the current status of the use of in silico-based approaches to aspects of molecular imprinting. Finally, we highlight areas where ongoing and future efforts should yield information critical to our understanding of the underlying mechanisms sufficient to permit the rational design of molecularly imprinted polymers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.