Objective Patients with healed venous ulcers often experience recurrence of ulceration, despite the use of long-term compression therapy. This study examines the effect of closing incompetent perforating veins (IPVs) on ulcer recurrence rates in patients with progressive lipodermatosclerosis and impending ulceration. Methods Patients with nonhealing venous ulcers of >2 months’ duration underwent duplex ultrasound to assess their lower extremity venous system for incompetence of superficial, perforating, and deep veins. Endovenous laser ablation (EVLA) of perforating veins was performed on patients with CEAP 6 disease with increasing hyperpigmentation, lipodermatosclerosis, and/or progressive malleolar pain. A minimum of 2 months of compressive therapy was attempted before endovenous ablation of IPVs. Demographic data, risk factors, CEAP classification, procedural details, and postoperative status were all recorded. Results Forty ulcers with 46 associated IPVs were treated with EVLA in 36 patients with CEAP 6 recalcitrant venous ulcers. Treated incompetent perforator veins were located in the medial ankle (85.7%), calf (10.7%), and lateral ankle (3.5%). Endovenous laser ablation was successful in 76% (35/46) with the first laser treatment of incompetent perforator veins and 15.2% (7/46) additional ablation procedures were performed. Of the 46 treated IPVs, 42 (91.3%) were occluded on the duplex examination at 12 months. The average energy administrated per perforating vein treated was 162 joule. Two patients reported localized paresthesia, which subsided spontaneously, but no deep venous thrombosis or skin burn was observed. Conclusion Especially in the case of liposclerotic or ulcerated skin in the affected region, PAP of IPVs is highly effective, safe, and appears to be feasible. Patients with active venous ulcers appear to benefit from EVLA of incompetent perforators in order to reduce the risk of ulcer recurrence.
Development of stroke is one of the major reasons of mortality after coronary artery bypass operations. It is essential to take all the measures to prevent this complication, especially in patients with known risk factors. Evaluation of carotid arteries prior to operation and application of routine intraoperative epiaortic echocardiography may in part eliminate stroke.
The effects of pulsatile perfusion on microcirculation and renal function in high-risk patients were evaluated in this study. Pulsatile roller pumps with a pulsatile control module and membrane oxygenator were used in a clinical setting. 40 patients undergoing elective cardiac surgery with a high risk of either having chronically obstructive pulmonary disease or chronic renal failure were randomly included in the study to be perfused using pulsatile or continuous flows. Blood samples were collected at induction of anesthesia, at the time of aortic clamping and declamping and 1 and 24 h following cessation of the bypass. Urea and creatinine concentrations in blood were measured and systemic vascular resistance was calculated. Urine output, crystalloid and colloid infusions were recorded. We observed that pulsatile roller pump perfusion and the extracorporeal circuit used in the clinical study improved microcirculation and renal function in high-risk patients undergoing cardiopulmonary bypass.
The importance of minimally invasive cardiac operations, performed off-pump, without the support of cardiopulmonary bypass (CPB), is continuously increasing. Complete revascularization of obstructed coronary arteries is needed to obtain a better long-term outcome. Insertion into the left ventricle of an efficient microaxial pump can be useful when targeting an important coronary artery located at posterior wall of the heart in a patient with hemodynamic deficiency. The use of such a device can enable surgeons to avoid conversion from a preplanned off-pump strategy to traditional on-pump coronary bypass surgery. The Impella Microaxial Ventricular Assist Device (VAD) (Abiomed, Aachen, Germany) is a miniature pump with a 7-mm catheter and a flow rate of approximately 2.5-5 L/min. This device can enable cardiovascular surgery to be performed without damaging the left ventricle and causing serious aortic deficiency. Therefore, in patients with serious comorbidity, complete revascularization may be performed off pump, with the heart beating, because of the hemodynamic stability provided with the support of the microaxial intracardiac pump. If required, this pump can also support the heart during the early postoperative period. We report the first assisted beating-heart coronary artery bypass graft surgery performed with the Impella Microaxial VAD in our country. The surgery was performed on 2 patients considered high risk on the basis of EUROSCORE testing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.