Ertugliflozin and Sitagliptin is combination of Antidiabetic drug in tablet Steglujan 15 mg/100 mg film-coated tablets®, a member Antidiabetic drug, is a recent drug developed by Merck Sharp and Dohme Company for the treatment of Type 2 diabetes. Ertugliflozin and Sitagliptin can be used alone or in combination therapy. A highly sensitive, precise and accurate Liquid Chromatography with mass spectrometry (LC-MS/MS) method is developed and validated for the determination of Ertugliflozin and Sitagliptin in combined formulation. Chromatographic separation was carried out on Phenomenex Gemini, C18, (150 × 4.6 mm,5 μm) column. Isocratic method was based on 0.1% formic acid: acetonitrile (10:90, v/vas mobile phase, column temperature at 40°C and flow rate at 0.6 mL/minuteswere utilized. The mass spectrometer was operated under multiple reactions monitoring (MRM) mode using electrospray ionization by monitoring the transition pair (precursor to product ion) of m/z 437.10-328.95in the positive mode for Ertugliflozin and transition pair (precursor to product ion) of m/z 408.10-234.95 in the positive mode for Sitagliptin. The method was found linear in the concentration range of 15 to 450 ng/mL and 100–3000 ng/mL for Ertugliflozin and Sitagliptin respectively. The optimized method was validated according to the International Conference on Harmonization (ICH) and FDA guidelines. The developed method was found suitable for the quantitation of Ertugliflozin and Sitagliptin in Pharmaceutical dosage form.
Metformin Hydrochloride and Gemigliptin is combination of Antidiabetic drug in tablet Zemimet SR ® Tablet (25/500 mg), a member Antidiabetic drug, is a recent drug developed by LG Life sciences for the treatment of Type 2 diabetes. A new sensitive and rapid HPLC method was developed for the determination of Metformin Hydrochloride and Gemigliptin in pharmaceutical dosage forms; it was validated according to International Conference on Harmonization and Food and Drug Administration guidelines. The analysis was performed on the HPLC system equipped with a using Gemni C18, (5 µm) (250 mm x 4.6 mm), with of Buffer (20mM Ammonium Acetate in water, pH 3.5) and Methanol: Acetonitrile 40:10 (%V/V) 60: 40 v/v with at a flow rate of 1.0 mL/min, column temperature 35°C, total run time was 10 min, injection volume 10 μl, and detection was performed at the wavelength (λ) of 265 nm. The calibration plot gave linear relationship over the concentration range of Metformin Hydrochloride 20, 40, 100, 200, 400 and 500 μg/ml, and Gemigliptin 1, 2, 5, 10, 20 and 25 μg/ml, respectively. The accuracy of the proposed method was determined by recovery studies and was found to be Metformin Hydrochloride 99.0 % to 101.0 % and Gemigliptin 98.0 % to 100.0 %.The Limit of Detection were 50.56 and 14.21 μg/ml for Metformin Hydrochloride and Gemigliptin, respectively and the Limit of Quantitation were 166.85 and 43.90 μg/ml for Metformin Hydrochloride and Gemigliptin, respectively% Relative Standard Deviation of the determination of precision was <2%. The results of robustness and solutions stability studies were within the acceptable limits as well the main features of the developed method are low run time and retention time of around 2.9 min for Metformin Hydrochloride (Met) and 7.4 min for Gemigliptin.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.