The single thermal energy storage tank (STEST) has been extensively investigated because of the advantage of cost and efficiency. This research presents heat discharging performance of STEST using coil heat exchanger (CHE) with annular baffle at different working conditions. The heat discharging performance, flow field and temperature distribution of different parameters of the annular baffle are presented and discussed. The results show that the heat discharging time decreases with an increase inlet air velocity of the CHE. The heat discharging efficiency is up to 95.7% in this study, and the heat discharging time can reach to 18.7 hours. In addition, optimal dimensionless diameters of annular baffle are D b /D t = 0.6, H s /H t = 0.075 and H x /H t = 0.050 (H s is the height from the top of baffle to the top of tank. H t is the height of the tank. H x is the height from bottom of the baffle to the bottom of the tank). The efficiency of heat discharging process can be enhanced with optimal dimensions of the annular baffle. This study presents a direct practicable guide to design the STEST. K E Y W O R D S annular baffle, coil heat exchanger, heat discharging, single thermal energy storage tank
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.