We show that inspection with an optical microscope allows surprisingly simple and accurate identification of single and multilayer graphene domains in epitaxial graphene on silicon carbide (SiC/G) and is informative about nanoscopic details of the SiC topography, making it ideal for rapid and noninvasive quality control of as-grown SiC/G. As an illustration of the power of the method, we apply it to demonstrate the correlations between graphene morphology and its electronic properties by quantum magneto-transport.
A major issue for the implementation of large-scale superconducting quantum circuits is the interaction with interfacial two-level system (TLS) defects that lead to qubit parameter fluctuations and relaxation. Another major challenge comes from nonequilibrium quasiparticles (QPs) that result in qubit relaxation and dephasing. Here, we reveal a previously unexplored decoherence mechanism in the form of a new type of TLS originating from trapped QPs, which can induce qubit relaxation. Using spectral, temporal, thermal, and magnetic field mapping of TLS-induced fluctuations in frequency tunable resonators, we identify a highly coherent subset of the general TLS population with a low reconfiguration temperature ∼300 mK and a nonuniform density of states. These properties can be understood if the TLS are formed by QPs trapped in shallow subgap states formed by spatial fluctutations of the superconducting order parameter. This implies that even very rare QP bursts will affect coherence over exponentially long time scales.
Two series/parallel arrays of ten cold-electron bolometers with superconductor-insulator-normal tunnel junctions were integrated in orthogonal ports of a cross-slot antenna. To increase the dynamic range of the receiver, all single bolometers in an array are connected in parallel for the microwave signal by capacitive coupling. To increase the output response, bolometers are connected in series for dc bias. With the measured voltage-to-temperature response of 8.8 µV/mK, absorber volume of 0.08 µm 3 , and output noise of about 10 nV/Hz 1/2 , we estimated the dark electrical noise equivalent power (NEP) as NEP = 6 * 10 −18 W/Hz 1/2 . The optical response down to NEP = 2 * 10 −17 W/Hz 1/2 was measured using a hot/cold load as a radiation source and a sample temperature down to 100 mK. The fluctuation sensitivity to the radiation source temperature is 1.3 * 10 −4 K/Hz 1/2 . A dynamic range over 43 dB was measured using a backward-wave oscillator, a variable polarization grid attenuator, and cold filters/attenuators.
We present fast tunable superconducting microwave resonators fabricated from planar NbN on a sapphire substrate. The 3λ/4 wavelength resonators are tuning fork shaped and tuned by passing a dc current that controls the kinetic inductance of the tuning fork prongs. The λ/4 section from the open end operates as an integrated impedance converter that creates a nearly perfect short for microwave currents at the dc terminal coupling points, thus preventing microwave energy leakage through the dc lines. We measure an internal quality factor Q int > 10 5 over the entire tuning range. We demonstrate a tuning range of greater than 3% and tuning response times as short as 20 ns for the maximum achievable detuning. Because of the quasifractal design, the resonators are resilient to magnetic fields of up to 0.5 T.
An important phenomenon limiting the sensitivity of bolometric detectors for future space missions is the interaction with cosmic rays. We tested the sensitivity of Cold Electron Bolometers (CEBs) to ionizing radiation using gamma-rays from a radioactive source and X-rays from an X-ray tube. We describe the test setup and the results. As expected, due to the effective thermal insulation of the sensing element and its negligible volume, we find that CEBs are largely immune to this problem
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.