Background: Aim of the study was to identify risk factors and to assess neonatal mortality and morbidity associated with preterm delivery in patient attending a tertiary care centre in rural Haryana.Methods: This retrospective cohort study was conducted in Shree Guru Gobind Singh Tricentenary Medical College, over a period of one year (January to December). All pre-term deliveries were included in the study. They were followed up from admission till delivery and till discharge from hospital. Various, parameters like maternal age, associated medical disorder, obstetric complications, gestational age, neonatal mortality, need of neonatal intensive care and condition of baby at discharge were analyzed.Results: In the present study, incidence of preterm deliveries was 16.1%. The most common risk factor found to be history of previous abortion (23.6%), preterm premature rupture of membrane (17.1%), Intra-uterine growth restriction (IUGR) with oligohydramnios (10.5%), hypertensive disorder during pregnancy (5.9%), and antepartum hemorrhage (4.6%). But majority of the patient (56.5%) no cause could be identify. Out of total 160 preterm births 3 were still born and 157 live preterm births, and out of which total Neonatal intensive care (NICU) admission were 60. Mortality rate was 100% in neonate weighing less than 1000 gm and 18% in babies weighing less than 2000 gm.Conclusions: The commonest risk factor for preterm delivery is previous history of abortion and adverse perinatal outcome is inversely proportionate to the period of gestation at the time of delivery. All efforts should be made to prolong the pregnancy beyond 34 weeks by identifying and actively managing the risk factors for better neonatal outcome.
Treatment of angle fractures remains controversial. The various techniques documented for the treatment are: wire osteosynthesis, one miniplate at superior border (2.0 mm), a single plate on inferior border (2.3 or 2.7 mm) along with tension band in the form of arch bar at the upper border, 2 miniplates (1 at superior border and 1 at inferior border), 3-D strut plates or lag screw. To evaluate the efficacy of single Y-shaped titanium miniplate at the superior border in the management of mandibular angle fractures. Total of 15 healthy adult patients reporting to the department of Oral and Maxillofacial Surgery for the treatment of mandibular angle fractures was randomly selected. All the cases were assessed clinically at 1st postoperative day, 1st, 3rd, 6th and 12th week post-operatively for pain, status of occlusion, neurosensory deficit and postoperative hard & soft tissue healing. Radiographic assessment was also done at 1st postoperative day, 6 weeks and 12 weeks. Postoperative pain, infection, wound dehiscence, neurosensory deficit were not evident during the follow-up periods. Radiographically, the fracture reduction was good and plate fracture was not seen in any case. Y-shaped titanium miniplate is an effective method in the management of the mandibular angle fractures and provided satisfactory results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.