Background The intracompartmental septum in the first extensor compartment in patients with de Quervain's disease has been associated with disease development and prognosis. However, with the exception of surgical exploration, there is no way of detecting the septum. Questions/Purposes We evaluated the accuracy of sonography for identifying the intracompartmental septum in the first extensor compartment in patients with de Quervain's disease using surgical findings as the reference standard. Patients and Methods We performed surgical release of the first extensor compartment in 43 wrists of 40 patients who were unresponsive to nonoperative treatment. In each case, a sonographic evaluation was performed before surgery by a radiologist and the sonographic and surgical findings were compared. Results Sonography identified the intracompartmental septum in 19 of the 19 septum-present wrists and absence of the septum in 23 of the 24 septum-absent wrists. The sensitivity of sonography was 100% (95% confidence interval, 80%-100%), its specificity 96% (95% confidence interval, 78%-100%), accuracy 98% (95% confidence interval, 87%-100%), positive predictive value 95% (95% confidence interval, 74%-100%), and negative predictive value 100% (95% confidence interval, 83%-100%). Sonography also identified septum-like structures in 15 of 37 (41%) asymptomatic contralateral wrists.
BackgroundThe inferior alveolar nerve (IAN) may be injured during extraction of the mandibular third molar, causing severe postoperative complications. Many methods have been described for evaluating the relative position between the mandibular third molar and the inferior alveolar canal (IAC) on panoramic radiography and computed tomography, but conventional radiography provides limited information on the proximity of these two structures. The present study assessed the benefits of three-dimensional computed tomography (3D-CT) prior to surgical extraction of the mandibular third molar, to prevent IAN damage.MethodsThis retrospective study included 4917 extractions in 3555 patients who presented for extraction of the mandibular third molars. The cases were classified into three groups, according to anatomical relationship between the mandibular third molars and the IAC on panoramic radiography and whether 3D-CT was performed. Symptoms of IAN damage were assessed using the touch-recognition test. Data were compared using the chi-square test and Fisher’s exact test.ResultsAmong the 32 cases of IAN damage, 6 cases were included in group I (0.35 %, n = 1735 cases), 23 cases in group II (1.1 %, n = 2063 cases), and 3 cases in group III (0.27 %, n = 1119 cases). The chi-square test showed a significant difference in the incidence of IAN damage between groups I and II. No significant difference was observed between groups I and III using Fisher’s exact test. In the 6 cases of IAN damage in group I, the mandibular third molar roots were located lingual relative to the IAC in 3 cases and middle relative to the IAC in 3 cases. The overlap was ≥2 mm in 3 of 6 cases and 0–2 mm in the remaining 3 cases. The mean distance between the mandibular third molar and IAC was 2.2 mm, the maximum distance 12 mm, and the minimum distance 0.5 mm. Greater than 80 % recovery was observed in 15 of 32 (46.8 %) cases of IAN damage.Conclusions3D-CT may be a useful tool for assessing the three-dimensional anatomical relationship and proximity between the mandibular third molar and IAC in order to prevent IAN damage during extraction of mandibular third molars.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.