Background: This clinical case presented a novel method of segmental mandible reconstruction using 3D-printed titanium implant with pre-mounted dental implants that was planned to rehabilitate occlusion. Case presentation: A 53-year-old male who suffered osteoradionecrosis due to the radiation after squamous cell carcinoma resection. The 3D-printed titanium implant with pre-mounted dental implant fixtures was simulated and fabricated with selective laser melting method. The implant was successfully inserted, and the discontinuous mandible defect was rehabilitated without postoperative infection or foreign body reaction during follow-ups, until a year. Conclusions: The 3D-printed titanium implant would be the one of the suitable treatment modalities for mandible reconstruction considering all the aspect of mandibular functions.
Objectives: The purpose of this study was to evaluate the effectiveness of the intraoral use of subperiosteally placed self-inflating tissue expanders for subsequent bone augmentation and implant integrity. Material and methods: A prospective, multicenter, randomized controlled trial was performed on patients requiring alveolar bone graft for dental implant insertion. Patients were assigned to three groups: tissue expansion and tunneling graft (TET group), tissue expansion and conventional bone graft (TEG), and control group without tissue expansion. Dimensional changes of soft tissue and radiographic vertical bone gain, retention, and peri-implant marginal bone changes were evaluated and secondary outcomes; clinical complications and thickness changes of expanded overlying tissue were assessed. Results: Among 75 patients screened, a total of 57 patients were included in the final analysis. Most patients showed uneventful soft tissue expansion without any inflammatory sign or symptoms. Ultrasonographic measurements of overlying gingiva revealed no thinning after tissue expansion (p > 0.05). Mean soft vertical and horizontal tissue measurements at the end of its expansion were 5.62 and 6.03 mm, respectively. Significantly higher vertical bone gain was shown in the TEG (5.71 ± 1.99 mm) compared with that in the control patients (4.32 ± 0.97 mm; p < 0.05). Hard tissue retention— measured by bone resorption after 6 months—showed that control group showed higher amount of vertical (2.06 ± 1.00 mm) and horizontal bone resorption (1.69 ± 0.81 mm) compared to that of the TEG group (p < 0.05). Conclusion: The self-inflating tissue expander effectively augmented soft tissue volume and both conventional bone graft and tunneling techniques confirmed their effectiveness in bone augmentation. With greater amount of bone gain and better 6 month hard tissue integrity, the TEG group compared to the control group—without tissue expansion—showed that the combined modality of tissue expander use and guided bone regeneration (GBR) technique may improve the outcome and predictability of hard tissue augmentation.
Background: The purpose of this study was to compare the effectiveness of absorbable collagen sponge insertion in tooth extraction sites for socket healing of the impacted mandibular third molar. Methods: Thirty-six patients with bilateral mandibular impacted third molars based on Pell-Gregory and Winter classification were included in this study. This study was a randomized clinical trial utilizing a split-mouth design with one side assigned as collagen sponge insertion and the other side assigned as the control. Post-operative clinical complications, periodontal integrities, and radiographic outcomes were assessed at 1, 2, and 14-weeks post operatively. Results: Five patients were excluded during the follow-up period due to loss of follow-up. The study was conducted on 31 patients in total. The mean VAS score of collagen sponge insertion side at 1 week post operation was 1.42 ± 1.26, which was significantly lower than the control side (P < 0.05). The mean probing depth of collagen sponge insertion side at 2-week post operation was 5.55 ± 2.28 mm, which was significantly lower than the control side (7.13 ± 1.86; P < 0.05). Other various measurements including radiographic outcomes showed no significant group differences. Conclusions: Placement of collagen sponge after extraction of mandibular impacted third molar reduced early stage post-operative complications and enhanced initial healing of soft tissues and periodontal defects. Trial registration: This study was retrospectively registered at the WHO ICTRP platform and Clinical Research Information Service, KCT0003363. Registered 21 Sep 2018.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.