To identify suitable cases and reduce failure/complication rates for percutaneous ventricular septal defect (VSD) closure, we aimed to (1) study causes of device failure and (2) compare outcomes with different VSD types and devices in a high-volume single center with limited resources. Retrospective data of 412 elective percutaneous VSD closure of isolated congenital VSDs between 2003 and 2017 were analyzed. Out of 412, 363 were successfully implanted, in 30 device implantation failed, and in 19 the procedure was abandoned. Outcome was assessed using echocardiography, electrocardiography, and catheterization data (before procedure, immediately after and during follow-up). Logistic regression analyses were performed to assess effects of age, VSD type, and device type and size on procedural outcome. Median [interquartile range] age and body surface area were 6.
A male child, with d-transposition of great arteries, a large perimembranous ventricular septal defect, multiple additional ventricular septal defects, small muscle-bound right ventricle, and severe pulmonary stenosis with confluent, moderate-sized branch pulmonary arteries, underwent an emergency right modified Blalock-Taussig shunt on day 15 of life and réparation à l'étageventriculaire procedure with ventricular septal defect closure with takedown of the Blalock-Taussig shunt at 2.5 years of age. On follow-up, he showed a moderate residual upper ventricular septal defect and multiple apical ventricular septal defects, mild mid-right pulmonary artery stenosis, free pulmonary regurgitation, and right ventricular dysfunction. Surgical re-intervention was deemed extremely risky, the upper muscular ventricular septal defect was closed using an 8-mm Amplatzer Muscular Ventricular Septal Defect Occluder Device, and an 18 mm Amplatzer Multi-Fenestrated Septal Occluder - Cribriform was used for the multiple apical muscular ventricular septal defects. After 1 year, his right pulmonary artery stenosis worsened, for which right pulmonary artery angioplasty was carried out using an 8×20 mm cutting balloon followed by a 10×20 mm Tyshak II balloon. This is the only case reported for the paediatric age group using a cribriform septal occluder device for percutaneous closure of multiple apical ventricular septal defects.
Introduction:The early identification of vulnerable pediatric cardiac surgery patients can help clinicians provide them with timely support. Heart-type fatty acid-binding protein. (H-FABP) is an early biomarker of myocardial injury in acute myocardial infarction in adults. In this study, we evaluated the correlations between postoperative H-FABP, creatine kinase-myocardial band (CK-MB), troponin-I, total bypass time, and clinical outcomes.Methods:In 32 pediatric patients that underwent ventricular septal defect. closure we measured H-FABP, troponin-I and CK-MB preoperatively and 1, 3, and 6 h after aortic declamping. Spearman's Rho correlations were calculated between laboratory and clinical parameters including inotropic support duration, aortic cross-clamp time, total bypass time, ventilation-weaning-time, and total Intensive Care Unit stay.Results:H-FABP, CK-MB, troponin-I, and total bypass time have a similarly weak to moderate correlation with clinical outcome measures.Conclusions:The predictive value of H-FABP for clinical outcome is not stronger than that of CK-MB, Troponin-I, or bypass times.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.