This study analyzed the relationship between CrossFit performance and power and strength variables measured in the full-squat exercise. Twenty male trained subjects (33±7 years) performed an incremental load full-squat test for assessment of the 1-repetition maximum (1RM) and the mean (Pmean) and peak (Ppeak) power. Performance in 5 different Workouts of the Day (WODs) was measured on different days, and overall CrossFit performance was determined as the sum of the scores obtained in these WODs. Athletes were then assigned to a high (HP) or low (LP) performance group based on the median score for overall performance. Correlation analysis between squat variables and performance was performed and between-group differences were assessed. Moderate to strong (r=0.47–0.69, p<0.05) positive correlations were found between squat variables and performance in the different WODs. Overall CrossFit performance was strongly and positively associated with absolute (r=0.62, p=0.01) and relative 1RM (r=0.65, p=0.07), and relative Pmean (r=0.56, p=0.02) and Ppeak (r=0.53, p=0.03). Large differences (effect sizes ranging 1.1–1.7, all p<0.05) were observed between HP and LP for absolute and relative 1RM, relative Pmean, and absolute and relative Ppeak. In summary, strength and power indexes measured in a squat test are positively associated with CrossFit performance.
The aim of this study was to determine the physiological variables that predict competition performance during a CrossFit competition. Fifteen male amateur CrossFit athletes (age, 35 ± 9 years; CrossFit experience, 40 ± 27 months) performed a series of laboratory-based tests (incremental load test for deep full squat and bench press; squat, countermovement and drop jump tests; and incremental running and Wingate tests) that were studied as potential predictors of CrossFit performance. Thereafter, they performed the five Workouts of the Day (WODs) corresponding to the CrossFit Games Open 2019, and we assessed the relationship between the laboratory-based markers and CrossFit performance with regression analyses. Overall CrossFit performance (i.e., final ranking considering the sum of all WODs, as assessed by number of repetitions, time spent in exercises or weight lifted) was significantly related to jump ability, mean and peak power output during the Wingate test, relative maximum strength for the deep full squat and the bench press, and maximum oxygen uptake (VO2max) and speed during the incremental test (all p < 0.05, r = 0.58–0.75). However, the relationship between CrossFit Performance and most laboratory markers varied depending on the analyzed WOD. Multiple linear regression analysis indicated that measures of lower-body muscle power (particularly jump ability) and VO2max explained together most of the variance (R2 = 81%, p < 0.001) in overall CrossFit performance. CrossFit performance is therefore associated with different power-, strength-, and aerobic-related markers.
The time to exhaustion (tlim) at the respiratory compensation point (RCP) and whether a physiological steady state is observed at this workload remains unknown. Thus, this study analyzed tlim at the power output eliciting the RCP (tlim at RCP), the oxygen uptake (VO2) response to this effort, and the influence of endurance fitness. Sixty male recreational cyclists (peak oxygen uptake [VO2peak] 40–60 mL∙kg∙min−1) performed an incremental test to determine the RCP, VO2peak, and maximal aerobic power (MAP). They also performed constant-load tests to determine the tlim at RCP and tlim at MAP. Participants were divided based on their VO2peak into a low-performance group (LP, n = 30) and a high-performance group (HP, n = 30). The tlim at RCP averaged 20 min 32 s ± 5 min 42 s, with a high between-subject variability (coefficient of variation 28%) but with no differences between groups (p = 0.788, effect size = 0.06). No consistent relationships were found between the tlim at RCP and the different fitness markers analyzed (RCP, power output (PO) at RCP, VO2peak, MAP, or tlim at MAP; all p > 0.05). VO2 remained steady overall during the tlim test, although a VO2 slow component (i.e., an increase in VO2 >200 mL·min−1 from the third min to the end of the tests) was present in 33% and 40% of the participants in HP and LP, respectively. In summary, the PO at RCP could be maintained for about 20 min. However, there was a high between-subject variability in both the tlim and in the VO2 response to this effort that seemed to be independent of fitness level, which raises concerns on the suitability of this test for fitness assessment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.