The use of higher dosages of neurohormonal blockers and lower dosages of diuretics is associated with reduced morbidity and mortality following CRT implantation. Our data imply a beneficial effect of increasing neurohormonal blockade whenever possible following CRT implantation.
Background: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in patients suffering from chronic heart failure (CHF (17.5% and 28.4% for sAV and pAV, respectively). In contrast, interventricular delay (VV delay) was rarely changed (11.9%). Conclusions: In our "real world" cohort, a substantial proportion of patients presented to their first post-operative consultation with suboptimal device settings. Our data indicate that the opportunity to optimize device settings is frequently wasted in the "real world", underlining the necessity for expert device follow-up to deliver optimal care to this challenging group of heart failure patients. (Cardiol J 2014; 21, 3: 316-324)
This systematic review suggests similar rates of complications but higher rates of colonic restoration after primary anastomosis compared to Hartmann procedure in perforated diverticulitis with generalized peritonitis (Hinchey III and IV). Results in laparoscopic lavage for Hinchey III are not superior to primary resection. However, further studies with a careful interpretation of the meaning of re-interventions are required.
Beneficial effects of antenatal glucocorticoid treatment in pregnancies at risk for preterm delivery may entail long-term consequences for the establishment of sympathoadrenergic system balance. We analyzed the cardiac autonomic system activity in neonates with a single course of antenatal betamethasone (2 × 12 mg) treatment by calculating heart rate variability (HRV) time-domain parameters from 24 h ECG recordings and short-term frequency-domain parameters during infant active and resting states. In addition, resting and challenged salivary α-amylase levels were measured in 23 betamethasone-exposed neonates and compared with controls. Indicators for overall HRV (SDNN: p = 0.258; triangular index: p = 0.179) and sympathovagal balance [low- to high-frequency power (LF/HF): p = 0.82 (resting state)] were not significantly different in neonates of the betamethasone treatment group. Parameters mostly influenced by sympathetic activity [SD of the average of valid NN intervals (SDANN): p = 0.184 and SDs of all NN intervals (SDNNi): p = 0.784] and vagal tone [RMSSD: p = 1.0; NN50: p = 0.852; HF: p = 0.785 (resting state)] were unaltered. Resting α-amylase levels were not significantly different in the betamethasone treatment group (p = 0.304); however, α-amylase release after a neonatal challenge was slightly reduced (p = 0.045). Thus, cardiac autonomic balance seems to be preserved in neonates exposed to a single course of antenatal betamethasone treatment.
BackgroundCardiac resynchronization therapy (CRT) has become an important pillar of contemporary heart failure therapy. The efficacy of CRT, however, critically relies on proper LV lead placement and performance, which is why data regarding the long-term performance of CS leads are of considerable interest. Available studies are limited by a restricted variety of lead vendors, earlier lead models and / or very short follow-up periods. In the current study, we therefore investigated the long-term performance of modern LV leads in a large "real world" cohort of patients undergoing CRT implantation.Methods and ResultsAll 193 patients who had successfullyundergone CRT implantation at the University Hospital Zurich between September 2003 and January 2010 were included in the study. An overall stable course of stimulation energy was observed over time; neither ischemic etiology, lead configuration, or severely reduced EF had an influence on the evolution of energy thresholds over time. Interestingly, patients with a high energy threshold at baseline experienced a significant reduction during follow-up. In contrast, a significant drop in impedance was seen following implantation, followed by a steady course for the rest of the observation period. Only 15 patients (9.7%) showed an impedance > 1000 Ohm at any time during their follow-up. Seven lead dislocations were observed during follow up.ConclusionThe current comprehensive analysis of long-term performance of modern coronary sinus leads demonstrates excellent stability, performance and safety. These data may have important implications for physicians involved in biventricular pacemaker implantations and in the follow-up care of these patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.