Background: An anastomotic leak (AL) after a restorative proctocolectomy and an ileal J-pouch increases morbidity and the risk of pouch failure. Thus, a perfusion assessment during J-pouch formation is crucial. While indocyanine green near-infrared fluorescence (ICG-NIRF) has shown potential to reduce ALs, its suitability in a restorative proctocolectomy remains unclear. We aimed to develop a standardized approach for investigating ICG-NIRF and ALs in pouch surgery. Methods: Patients undergoing a restorative proctocolectomy with an ileal J-pouch for ulcerative colitis at an IBD-referral-center were included in a prospective study in which an AL within 30 postoperative days was the primary outcome. Intraoperatively, standardized perfusion visualization with ICG-NIRF was performed and video recorded for postoperative analysis at three time points. Quantitative clinical and technical variables (secondary outcome) were correlated with the primary outcome by descriptive analysis and logistic regression. A novel definition and grading of AL of the J-pouch was applied. A postoperative pouchoscopy was routinely performed to screen for AL. Results: Intraoperative ICG-NIRF-visualization and its postoperative visual analysis in 25 patients did not indicate an AL. The anastomotic site after pouch formation appeared completely fluorescent with a strong fluorescence signal (category 2) in all cases of ALs (4 of 25). Anastomotic site was not changed. ICG-NIRF visualization was reproducible and standardized. Logistic regression identified a two-stage approach vs. a three-stage approach (Odds ratio (OR) = 20.00, 95% confidence interval [CI] = 1.37–580.18, p = 0.029) as a risk factor for ALs. Conclusion: We present a standardized, comparable approach of ICG-NIRF visualization in pouch surgery. Our data indicate that the visual interpretation of ICG-NIRF alone may not detect ALs of the pouch in all cases—quantifiable, objective methods of interpretation may be required in the future.
Gracilis muscle interposition (GMI) is an established treatment option for complex perineal fistulas and reconstruction. The outcome is limited by complications such as necrosis, impaired wound healing and fistula persistence or recurrence. Quantifiable methods of assessing muscle flap perfusion intraoperatively are lacking. This study evaluates a novel and objective software-based assessment of indocyanine green near-infrared fluorescence (ICG-NIRF) in GMI. Methods: Intraoperative ICG-NIRF visualization data of five patients with inflammatory bowel disease (IBD) undergoing GMI for perineal fistula and reconstruction were analyzed retrospectively. A new software was utilized to generate perfusion curves for the specific regions of interest (ROIs) of each GMI by depicting the fluorescence intensity over time. Additionally, a pixel-to-pixel and perfusion zone analysis were performed. The findings were correlated with the clinical outcome. Results: Four patients underwent GMI without postoperative complications within 3 months. The novel perfusion indicators identified here (shape of the perfusion curve, maximum slope value, distribution and range) indicated adequate perfusion. In one patient, GMI failed. In this case, the perfusion indicators suggested impaired perfusion. Conclusions: We present a novel, software-based approach for ICG-NIRF perfusion assessment, identifying previously unknown objective indicators of muscle flap perfusion. Ready for intraoperative real-time use, this method has considerable potential to optimize GMI surgery in the future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.