BackgroundThe primary goal of conventional endovascular and microvascular approaches is the clinical and radiological resolution of the symptomatic aneurysm-induced mass effect. This study assessed the volume changes and mass effect reduction due to sac shrinkage after treatment with flow diverter stents (FD) for unruptured cerebral aneurysms.MethodsWe analyzed retrospectively 36 symptomatic aneurysms that were larger or equal to 25 mm in diameter in patients treated at our center from January 2016 to April 2022. Radiological and clinical outcomes were analyzed, including aneurysmal volume changes and resolution of aneurysm-related symptoms.ResultsAt 6 months, 25 aneurysms decreased in size, 2 remained unchanged, and 9 aneurysms demonstrated a post-treatment dimensional increase. At 12 months, 30 aneurysms showed a progressive radiological volume reduction. Either no change or negligible shrinkage was observed in the remaining six aneurysms. At 24 months, 32 aneurysms showed aneurysmal shrinkage by a mean 47% volume loss with respect to baseline. At the last follow-up, all 13 patients who had presented with third cranial nerve palsy showed improvements. Complete reversal of the pretreatment edematous changes was confirmed in all cases. The overall post-treatment complication rate was 8.3%, as 3 patients experienced non-fatal delayed rupture of their aneurysm. There was no mortality in this study.ConclusionFlow diversion could effectively induce progressive aneurysmal shrinkage and resolution of the mass effect associated with giant symptomatic cerebral aneurysms.
Numerous devices and sophisticated strategies have been developed to further increase the number of aneurysms amenable to endovascular treatment.1–4 Despite the superfluity of available neurovascular armamentarium, wide-necked bifurcation aneurysms can still pose a significant technical challenge to the treating clinician.5–7 Neck bridging is a conceptually new approach, which provides increased occlusion rates with lower recurrence and complications rates.8–10 The Nautilus (EndoStream Medical) is an intrasaccular bridging device intended to assist in coil embolization of wide-necked cerebral aneurysms. This CE-marked device, available in various sizes, consists of flexible-layers, and is a nitinol-based, detachable implant. The device is delivered through a standard microcatheter with a minimal 0.0165" inner diameter and is fully radiopaque and completely resheathable.Owing to its unique ‘tornado’ like shape the device entirely reconstructs the aneurysmal neck, which facilitates the following coil embolization. In this video 1, we demonstrate the use of Nautilus - assisted coil embolization for a complex anterior communicating artery (AcomA) wide-necked aneurysm in the setting of acute subarachnoid hemorrhage.Video 1
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.