Background Intraoperative tissue analysis and identification are critical to guide surgical procedures and improve patient outcomes. Here, we describe the clinical translation and evaluation of the MasSpec Pen technology for molecular analysis of in vivo and freshly excised tissues in the operating room (OR). Methods An Orbitrap mass spectrometer equipped with a MasSpec Pen interface was installed in an OR. A “dual-path” MasSpec Pen interface was designed and programmed for the clinical studies with 2 parallel systems that facilitated the operation of the MasSpec Pen. The MasSpec Pen devices were autoclaved before each surgical procedure and were used by surgeons and surgical staff during 100 surgeries over a 12-month period. Results Detection of mass spectral profiles from 715 in vivo and ex vivo analyses performed on thyroid, parathyroid, lymph node, breast, pancreatic, and bile duct tissues during parathyroidectomies, thyroidectomies, breast, and pancreatic neoplasia surgeries was achieved. The MasSpec Pen enabled gentle extraction and sensitive detection of various molecular species including small metabolites and lipids using a droplet of sterile water without causing apparent tissue damage. Notably, effective molecular analysis was achieved while no limitations to sequential histologic tissue analysis were identified and no device-related complications were reported for any of the patients. Conclusions This study shows that the MasSpec Pen system can be successfully incorporated into the OR, allowing direct detection of rich molecular profiles from tissues with a seconds-long turnaround time that could be used to inform surgical and clinical decisions without disrupting tissue analysis workflows.
A physical understanding of membrane permeation and translocation by small, positively charged molecules can illuminate cell penetrating peptide mechanisms of entry and inform drug design. We have previously investigated the permeation of the doubly charged peptide WKW and proposed a defect-assisted permeation mechanism where a small molecule with +2 charge can achieve a metastable state spanning the bilayer by forming a membrane defect with charges stabilized by phospholipid phosphate groups. Here, we investigate the membrane permeation of two doubly charged peptides, WWK and WWWK, with charges separated by different lengths. Through complementary experiments and molecular dynamics simulations, we show that membrane permeation was an order of magnitude more favorable when charges were separated by an ∼2–3 Å greater distance on WWWK compared to WWK. These results agree with the previously proposed defect-assisted permeation mechanism, where a greater distance between positive charges would require a less extreme membrane defect to stabilize the membrane-spanning metastable state. We discuss the implications of these results in understanding the membrane permeation of cell-penetrating peptides and other small, positively charged membrane permeants.
The outbreak of COVID-19 has created an unprecedent global crisis. While the polymerase chain reaction (PCR) is the gold standard method for detecting active SARS-CoV-2 infection, alternative high-throughput diagnostic tests are of a significant value to meet universal testing demands. Here, we describe a new design of the MasSpec Pen technology integrated to electrospray ionization (ESI) for direct analysis of clinical swabs and investigate its use for COVID-19 screening. The redesigned MasSpec Pen system incorporates a disposable sampling device refined for uniform and efficient analysis of swab tips via liquid extraction directly coupled to an ESI source. Using this system, we analyzed nasopharyngeal swabs from 244 individuals including symptomatic COVID-19 positive, symptomatic negative, and asymptomatic negative individuals, enabling rapid detection of rich lipid profiles. Two statistical classifiers were generated based on the lipid information acquired. Classifier 1 was built to distinguish symptomatic PCR-positive from asymptomatic PCR-negative individuals, yielding a cross-validation accuracy of 83.5%, sensitivity of 76.6%, and specificity of 86.6%, and validation set accuracy of 89.6%, sensitivity of 100%, and specificity of 85.3%. Classifier 2 was built to distinguish symptomatic PCR-positive patients from negative individuals including symptomatic PCR-negative patients with moderate to severe symptoms and asymptomatic individuals, yielding a cross-validation accuracy of 78.4%, specificity of 77.21%, and sensitivity of 81.8%. Collectively, this study suggests that the lipid profiles detected directly from nasopharyngeal swabs using MasSpec Pen-ESI mass spectrometry (MS) allow fast (under a minute) screening of the COVID-19 disease using minimal operating steps and no specialized reagents, thus representing a promising alternative high-throughput method for screening of COVID-19.
Background Rapid identification of bacteria is critical to prevent antimicrobial resistance and ensure positive patient outcomes. We have developed the MasSpec Pen, a handheld mass spectrometry-based device that enables rapid analysis of biological samples. Here, we evaluated the MasSpec Pen for identification of bacteria from culture and clinical samples. Methods A total of 247 molecular profiles were obtained from 43 well-characterized strains of 8 bacteria species that are clinically relevant to osteoarticular infections, including Staphylococcus aureus, Group A and B Streptococcus, and Kingella kingae, using the MasSpec Pen coupled to a high-resolution mass spectrometer. The molecular profiles were used to generate statistical classifiers based on metabolites that were predictive of Gram stain category, genus, and species. Then, we directly analyzed samples from 4 patients, including surgical specimens and clinical isolates, and used the classifiers to predict the etiologic agent. Results High accuracies were achieved for all levels of classification with a mean accuracy of 93.3% considering training and validation sets. Several biomolecules were detected at varied abundances between classes, many of which were selected as predictive features in the classifiers including glycerophospholipids and quorum-sensing molecules. The classifiers also enabled correct identification of Gram stain type and genus of the etiologic agent from 3 surgical specimens and all classification levels for clinical specimen isolates. Conclusions The MasSpec Pen enables identification of several bacteria at different taxonomic levels in seconds from cultured samples and has potential for culture-independent identification of bacteria directly from clinical samples based on the detection of metabolic species.
Poison frogs are well-known for their fascinating ability to store alkaloids in their skin as chemical defense against predators. Chemical methods used to study these alkaloids are limited by requirements for euthanasia or stress during sampling. Here, we demonstrate sensitive and biocompatible alkaloid detection and monitoring in vivo using the MasSpec Pen, a handheld, noninvasive chemical detection device coupled to a mass spectrometer. The MasSpec Pen allowed rapid (<15 s), gentle, and consecutive molecular analysis without harm or undue stress to the animals. Through a month-long alkaloid-feeding study with the dyeing poison frog, we observed temporal dynamics of chemical sequestration in vivo by comparing frogs fed the alkaloid decahydroquinoline (DHQ) to vehicle-fed frogs. We also demonstrate the feasibility of the MasSpec Pen for the untargeted detection of rich alkaloid profiles from skin extracts of the Diablito poison frog, collected from two distinct geographical populations in Ecuador. The results obtained in this study demonstrate the utility of the MasSpec Pen for direct, rapid, and biocompatible analysis of poison frog alkaloids.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.