were followed for 3 months for venous thromboembolism (VTE). Results: Of the 913 included patients, 298 (33%) had a negative D-dimer result. One hundred and seventythree patients (18.9%) were diagnosed with DVT at baseline. One of 298 patients had DVT despite having a negative D-dimer result, resulting in a failure rate of 0.3% (95% confidence interval [CI] 0.1-1.9%). Adding the modified Wells score would have yielded a failure rate of 0.0% (95% CI 0.0-1.8%) while necessitating 87 more CUS examinations. Age-adjusted D-dimer as a standalone test would have necessitated 80 fewer CUS examinations than fixed D-dimer as a stand-alone test, at the cost of a failure rate of 1.6% (95% CI 0.7-3.4%). Conclusions: This outcome study shows that a negative high-sensitivity D-dimer result safely excludes DVT in an outpatient population, and necessitates fewer CUS than if used in combination with Wells score. The safety of stand-alone age-adjusted D-dimer needs further assessment in prospective outcome studies.
Background: Current guidelines recommend the use of clinical decision rules, such as Wells score, in combination with D-dimer to assess the need for objective imaging to rule out deep vein thrombosis (DVT). However, the clinical decision rule has limitations, and use of D-dimer as a stand-alone test has been suggested.
Objective:We aimed to assess the safety and efficiency of D-dimer as a stand-alone test to rule out DVT in outpatients referred with suspected DVT.
Methods:We collected data from consecutive outpatients referred to our hospital with suspected DVT in 2008-2018. D-dimer levels were analyzed using STA® Liatest® D-Di assay. D-dimer as a stand-alone test was theoretically applied in retrospect, and the number of misdiagnosed events were estimated as if such an approach had been initially used. All patients were followed for three months.Results: Of 1765 included patients, 293 (16.6%) were diagnosed with DVT. A total of 491 patients (27.8%) had a negative D-dimer (<500 ng/mL). Of these, nine were diagnosed with DVT, yielding a failure rate for D-dimer as a stand-alone test of 1.8% (95% CI 0.8%-3.5%). The majority of the misdiagnosed patients had distal DVT. In analyses restricted to proximal DVTs, the failure rate was 0.6% (95% CI 0.1%-1.8%). Ddimer as a stand-alone approach reduced the proportion of required ultrasounds from 81.8% to 72.2%.
Conclusion:D-dimer as a stand-alone test may be safe for excluding proximal DVT and reduce the proportion of required ultrasounds. Prospective management studies are needed to confirm our findings.
Highlights• D-dimer is proposed as a stand-alone test to rule out deep vein thrombosis (DVT).• We retrospectively explored the safety and efficiency of such a strategy in a large cohort.• Our findings suggest that D-dimer as a stand-alone test may be safe for excluding proximal DVT.• This strategy has the potential to simplify and increase the efficiency of the diagnostic work-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.