Leeds LS9 7TFIt has been shown that ultrasound and static isotope imaging are relatively insensitive for the detection of lesions <2cm diameter (Bryan et al., 1977). CAT scanning, although apparently more sensitive than these 2 methods still appears to have a limitation in detecting small lesions in the liver (Scherer et al., 1978). However, since it has been established that intrahepatic primary or secondary tumours are associated with an increased hepatic arterial blood flow (Breedis & Young, 1953) and time-activity curves generated. The time of the peak of the kidney curve was used to indicate the division between arterial and portal inflow phases of the liver curve. The quality of the bolus injection and its distribution was assessed by examination of the rise time of the kidney curve and studies were rejected if this was greater than 8 sec. After 3-point smoothing of the liver curve the average slopes of the 2 consecutive 8-second sections on either side of the arterial/portal division were calculated. The first slope was taken to represent arterial inflow and the second slope was taken to represent the portal inflow. The hepatic perfusion index (HPI) was expressed as a fraction of the arterial inflow to the total hepatic inflow. Static scans were independently assessed (P.J.R.) as being indicative or non-indicative of the presence of hepatic metastases. The results of the static and dynamic studies were correlated with findings at laparotomy for the presence or absence of hepatic metastases, which where possible were measured. The sites of these metastases were also noted. Figure 1 shows the distribution of HPI values in the positive laparotomy group, in the group of patients with no liver metastases and in the control group. It can be seen that 24/25 patients who were in the laparotomy positive group (96%) had HPI values above the normal range, the upper limit of normal in this series being 0.42. One patient with massive hepatic replacement by tumour had an HPI value of 0.15 but interestingly had a positive static scan. In those patients known to have hepatic involvement, the sensitivity of static scanning was 64%. Nine patients in this group had normal scans, but all had abnormal HPI values. The data for the negative laparotomy group are also shown but no definitive statement can be made until the follow-up
Radio and television announcements advised patients with surgical problems in the rural areas of Osun State, Nigeria, to report at any of the nine zonal headquarters of the state which were closest to their homes in order to receive free treatment. Over 1000 patients reported and 801 received operations on a rotational basis within nine weeks. We studied 719 of these patients, ages between 4 months and 87 years, who had detailed follow-up records. There were 14 different procedures ranging from a hernia repair to the separation of syndactyly. Complications included postoperative pain, haematoma and late superficial wound infection. We concluded that rotational free surgery can help the poor in the third-world countries to receive treatment that they would otherwise not be able to afford.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.