The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable.
Background and purposeThe Pipeline Embolization Device (PED) has become a routine first-line option for treatment of intracranial aneurysms (IAs). We assessed the early safety and technical success of a new version of PED, Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield), which has the same design and configuration but has been modified to include a surface synthetic biocompatible polymer.Materials and methodsThe Pipeline Flex Embolization Device with Shield Technology (PFLEX) study is a prospective, single-arm, multicenter study for the treatment of unruptured IAs using Pipeline Shield. The primary study endpoints included the occurrence of major stroke in the territory supplied by the treated artery or neurologic death at 1 year post-procedure. Secondary endpoints included the rate of Pipeline Shield-related or procedure-related serious or non-serious adverse events. Analyses were conducted to evaluate early safety findings in the 30-day post-procedure period as well as technical procedural success outcomes.ResultsFifty patients with 50 unruptured target IAs were enrolled. Mean aneurysm diameter was 8.82±6.15 mm. Thirty-eight aneurysms (76%) were small (<10 mm). Device deployment was technically successful with 98% of devices. Complete wall apposition was achieved immediately post-procedure in 48 cases (96%). No major strokes or neurologic deaths were reported in the 30-day post-procedure period.ConclusionsThe results of this first experience with the new Pipeline Flex corroborate the early safety of the device. Mid-term and long-term follow-up examinations will provide data on safety outcomes at the 6-month and 1-year follow-up periods. Clinical trial registrationNCT02390037.
PurposeThe Pipeline Embolization Device (PED) is a routine first-line treatment option for intracranial aneurysms (IAs). The Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield) is an updated version of the PED which has been modified to include a surface phosphorylcholine biocompatible polymer. Its early technical success and safety have been reported previously. Here, we assessed the long-term safety and efficacy of the Pipeline Shield for the treatment of IAs.Materials and methodsThe Pipeline Flex Embolization Device with Shield Technology (PFLEX) study was a prospective, single-arm, multicenter study for the treatment of unruptured IAs using the Pipeline Shield. The primary endpoint was a major stroke in the territory supplied by the treated artery or neurologic death at 1-year post-procedure. Angiographic outcomes were also assessed by an independent radiology laboratory at 6 months and 1 year.ResultsFifty patients (mean age, 53 years; 82% female) with 50 unruptured IAs were treated. Mean aneurysm diameter was 8.82±6.15 mm. Of the target aneurysms, 38/50 (76%) were small (<10 mm), 11/50 (22%) were large (≥10 and<25 mm), and 1/50 (2%) was giant (≥25 mm). Forty-seven (94%) were located in the internal carotid artery and three (6%) in the vertebral artery. At 1-year post-procedure, no major strokes or neurologic deaths were reported, and complete occlusion was achieved in 27/33 (81.8%). There were no instances of aneurysm recurrence or retreatment.ConclusionsOur 1-year follow-up concerning angiographic and safety outcomes corroborate previous evidence that the Pipeline Shield is a safe and effective treatment for IAs.Trial registration numberNCT02390037
Background and purpose The Woven EndoBridge (WEB) is an intrasaccular flowdisruptor that is increasingly used for the treatment of (wide-necked) aneurysms. We present our experience with the WEB for unruptured aneurysms. Materials and methods Between April 2014 and August 2019, 93 patients with 95 unruptured aneurysms were primarily treated with the WEB. There were 69 women and 24 men, mean age 61 years (median 58, range 37–80). Results Of 95 aneurysms, 86 had been discovered incidentally, 3 were symptomatic and 6 were additional to another ruptured aneurysm. Location was anterior communicating artery 33, middle cerebral artery 29, basilar tip 19, carotid tip 8, posterior communicating artery 4, posterior inferior cerebellar artery 1, superior cerebellar artery 1. Mean aneurysm size was 6 mm (median 6, range 3–13 mm). In one aneurysm additional coils were used and in another, a stent was placed. There was one procedural rupture without clinical sequelae. There were two thrombo-embolic complications leading to permanent deficit in one patient (mRS 2). Morbidity rate was 1.0% (1 of 93, 95%CI 0.01–6.5%) and mortality was 0% (0 of 93, 95%CI 0.0–4.8%). Angiographic follow-up at six months was available in 85 patients with 87 aneurysms (91%). Of 87 aneurysms, 68 (78%) were completely occluded, 14 (16%) had a neck remnant and 5 were incompletely occluded. Four aneurysms were retreated. Retreatment rate was 4.5% (4 of 87, 95%CI 1.7–13.6%). Conclusion WEB treatment of unruptured aneurysms is safe and effective. Additional devices are needed only rarely and retreatment at follow-up is infrequent.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.