Inhalation of cigarette smoke into the lower airway via a tracheostomy evokes immediate apnea, bradycardia, and systemic hypotension in dogs. These responses can still be evoked when conduction in myelinated vagal fibers is blocked preferentially by cooling but are abolished by vagotomy, suggesting that they are mediated by afferent vagal C-fibers. To examine this possibility, we recorded impulses in pulmonary C-fibers in anesthetized, open-chest dogs and delivered 120 ml cigarette smoke to the lungs in a single ventilatory cycle. Pulmonary C-fibers were stimulated within 1 or 2 s of the delivery of smoke generated by high-nicotine cigarettes, activity increasing from 0.3 +/- 0.1 to a peak of 12.6 +/- 1.3 (SE) impulses/s, (n = 60); the evoked discharge usually lasted 3-5 s. Smoke generated by low-nicotine cigarettes evoked a milder stimulation in 33% of pulmonary C-fibers but did not significantly affect the overall firing frequency (peak activity = 2.2 +/- 1.1 impulses/s, n = 36). Hexamethonium (0.7-1.2 mg/kg iv) prevented C-fiber stimulation by high-nicotine cigarette smoke (n = 12) but not stimulation by right atrial injection of capsaicin. We conclude that pulmonary C-fibers are stimulated by a single breath of cigarette smoke and that nicotine is the constituent responsible.
In anesthetized dogs we examined the sensitivity of afferent vagal endings in the lungs to changes in airway fluid osmolarity. Injection of 0.25-0.5 ml/kg water or hyperosmotic sodium chloride solutions (1,200-2,400 mmol/l) into a lobar bronchus caused bradycardia, arterial hypotension, apnea followed by rapid shallow breathing, and contraction of tracheal smooth muscle. All effects were abolished by vagotomy. We examined the sensory mechanisms initiating these effects by recording afferent vagal impulses arising from the lung lobe into which the liquids were injected. Water stimulated pulmonary and bronchial C-fibers and rapidly adapting receptors; isosmotic saline and glucose solutions were ineffective. Hyperosmotic saline (1,200-9,600 mmol/l, 0.25-1 ml/kg) stimulated these afferents in a concentration-dependent manner. Stimulation began 1-10 s after the injection and sometimes continued for several minutes. Responses of slowly adapting stretch receptors varied. Our results suggest that non-isosmotic fluid in the lower airways initiates defense reflexes by stimulating pulmonary and bronchial C-fibers and rapidly adapting receptors. Conceivably, stimulation of these afferents as a result of evaporative water loss from airway surface liquid could contribute to exercise-induced asthma.
We examined the steady-state response of slowly adapting pulmonary stretch receptors (SAPSRs) to reduced lung compliance in open-chest cats with lungs ventilated at eupneic rate and tidal volume (VT) and with a positive end-expiratory pressure (PEEP) of 3-4 cmH2O. Transient removal of PEEP decreased compliance by approximately 30% and increased transpulmonary pressure (Ptp) by 1-2.5 cmH2O. Reduction of compliance significantly decreased SAPSR discharge in deflation and caused a small increase in discharge at the peak of inflation; it had little effect on discharge averaged over the ventilatory cycle. Increasing VT to produce a comparable increase in Ptp significantly increased peak discharge. Thus unlike rapidly adapting receptors, whose discharge is increased more effectively by reduced compliance than by increased VT, SAPSRs are stimulated by increased VT but not by reduced compliance. We speculate that the most consistent effect of reduced compliance on SAPSRs (the decrease in deflation discharge) was due to the decreased time constant for deflation in the stiffer lung. This alteration in firing may contribute to the tachypnea evoked as the lungs become stiffer.
We examined the response of pulmonary rapidly adapting receptors (RAR's) to changes in dynamic lung compliance (Cdyn) in the physiological range. RAR impulse activity was recorded from the cervical vagus nerves in anesthetized open-chest dogs whose lungs were ventilated at constant rate and tidal volume (VT), with a positive end-expiratory pressure (PEEP) of 3-4 cmH2O. After hyperinflation to produce maximal Cdyn, RAR's were silent or fired sparsely and irregularly. Reducing Cdyn in steps by briefly removing PEEP increased firing proportionately, and RAR's began to discharge vigorously in inflation. Activity was restored to control by hyperinflating the lungs. Activity also increased when we increased inflation rate, and hence the rate of change of airway pressure (dP/dt), by reducing inflation time, keeping VT and cycle length constant. RAR's were stimulated more when dP/dt was increased by reducing compliance than when dP/dt was increased by increasing inflation rate. We conclude that RAR's are sensitive to changes in Cdyn and speculate that excitatory input from RAR's may help to maintain VT as the lungs become stiffer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with đź’™ for researchers
Part of the Research Solutions Family.