Abstract-We are planning to develop a 1 MW, 1 sec UPS-SMES for a protection from a momentary voltage drop and an instant power failure. As the first step, we have been developing a 100 kJ class prototype UPS-SMES, using a low temperature superconducting coil because of its better cost and performance over the high temperature superconducting coil. However, the difficulty to utilize a pool-boiling LTS pulse coil is the reliability of operation. To solve this problem, a conduction-cooled LTS pulse coil has been designed and fabricated as a key component of the UPS-SMES. The reduction of AC loss and high stability are required for the SC conductor for the conduction-cooled coil because of a limited cooling capacity. The SC conductor of a NbTi/Cu compacted strand cable extruded with an aluminum is designed to have the anisotropic AC loss properties to minimize the coupling loss under the specified orientation of the time varying magnetic field. The coil was wound with a new twist-winding method in which the variation of twist angle of the conductor was controlled with the winding machine designed specifically for this purpose. The fabrication technique and performance of a conduction-cooled prototype LTS pulse coil are described.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.