The results of this study show that a Tile C.1.2-type injury to the pelvic ring can be treated as effectively with ISS or SIF when combined anterior and posterior fixations are performed. SIF therefore seems reliable and its continued use is justified. The long-term clinical outcomes should nevertheless be evaluated, notably on the younger population, more often affected by this type of injury.
ObjectFew biomechanical in vitro studies have reported the effects of disc replacement on motion and kinematics of the cervical spine. The purpose of this study was to analyze motion through 3D load-displacement curves before and after implantation of a ball-and-socket cervical disc prosthesis with cranial geometric center; special focus was placed on coupled motion, which is a well-known aspect of normal cervical spine kinematics.MethodsSix human cervical spines were studied. There were 3 male and 3 female cadaveric specimens (mean age at death 68.5 ± 5 years [range 54–74 years]). The specimens were evaluated sequentially in 2 different conditions: first they were tested intact; then the spinal specimens were tested after implantation of a ball-and-socket cervical disc prosthesis, the Discocerv, at the C5–6 level. Pure moment loading was applied in flexion/extension, left and right axial rotation, and left and right lateral bending. All tests were performed under load control with a 3D measurement system.ResultsNo differences were found to be statistically significant after comparison of range of motion between intact and instrumented spines for all loading conditions. The mean range of motion for intact spines was 10.3° in flexion/extension, 5.6° in lateral bending, and 5.4° in axial rotation; that for instrumented spines was 10.4, 5.2, and 4.8°, respectively. No statistical difference was observed for the neutral zone nor stiffness between intact and instrumented spines. Finally, the coupled motions were also preserved during axial rotation and lateral bending, with no significant difference before and after implantation.ConclusionsThis study demonstrated that, under specific testing conditions, a ball-and-socket joint with cranial geometrical center can restore motion in the 3 planes after discectomy in the cervical spine while maintaining physiological coupled motions during axial rotation and lateral bending.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.