Objective: Aim of the present work is to develop a simple, accurate and precise stability-indicating method for the quantification of baloxavir marboxil (BLMX) in tablet dosage form by UPLC. Methods: Chromatographic elution was processed through a HSS C18 (100 x 2.1 mm, 1.8 mm) reverse phase column and the mobile phase composition of buffer 0.1% orthophosphoric acid and acetonitrile in the ratio of 50:50 was processed through a column at a flow rate of 0.3 ml/min. Column oven temperature was maintained at 30 °C and the detection wavelength was processed at 240 nm. Results: Retention time of BLMX was found to be 0.87 min. Repeatability of the method was determined in the form of %RSD and the value was 0.2. The percentage mean recovery of the method was found to be 99.47%. LOD, LOQ values obtained from the regression equation of BLMX were 0.69 and 2.10 mg/ml, respectively. Regression equation and correlation coefficient values of BLMX were y = 16994x+7179.2 and 0.9996. Drug was subjected for acid, peroxide, photolytic, alkali, neutral and thermal degradation studies and the results shown that the percentage of degradation was found between 5.96% and 9.55%. Conclusion: Retention time and total run time of the drug was decreased and the developed method was simple and economical. So, the developed method can be adopted in industries as a regular quality control test for the quantification of BLMX.
A simple, accurate and precise stability indicating method was developed for the simultaneous estimation of the encorafenib (ECRB) and binimetinib (BMTB) in a dosage form by UPLC. Chromatographic elution was processed through a HSS C18 (100 x 2.1 mm, 1.8m) reverse phase column and the mobile phase composition of 0.01N KH2PO4 buffer (3.5 pH) and acetonitrile in the proportion of 55:45 was processed thru a column at a flow rate of 1.0 ml/min. Temperature of the column oven was kept at 30.0°C and the wavelength maximum of detection system was set to 294 nm. Retention times of ECRB and BMTB were found to be 0.767 min and 1.130 min respectively. Repeatability of the method was determined in the form of %RSD and findings were 0.3 and 0.6 for ECRB and BMTB respectively. The percentage recovery of the method was found to be 99.59% and 99.70% for ECRB and BMTB respectively. LOD, LOQ values obtained from regression equations of ECRB and BMTB were 0.51, 1.55mg/ml and 1.47, 4.44 mg/ml respectively. Regression equation of ECRB was y = 6684.x + 18102 and BMTB was y = 13118x + 2159. Two analytes were subjected for acid, peroxide, photolytic, alkali, neutral and thermal degradation studies and the results shown that the percentage of degradation was found between 0.76% and 6.88%. Retention times and total run time of two drugs were decreased and the developed method was simple and economical. So, the developed method can be adopted in industries as a regular quality control test for the quantification of ECRB and BMTB.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.