Stress corrosion cracking tests were performed in both X-52 and X-60 weldments in sodium bicarbonate (NaHCO 3 ) solutions at 50 C using the Slow Strain Rate Testing (SSRT) technique. Solution concentrations varied between 0.1 to 0.0001 M, and to simulate the NS-4 solution, chloride (Cl À ) and/or sulfate (SO 2À 4 ) ions were added to the 0.01 M solution. Tests were complemented with hydrogen permeation measurements and polarization curves. It was found that the corrosion rate, taken as the corrosion current, I corr , was maximum in 0.01 M NaHCO 3 and with additions of SO 2À 4 ions. Higher or lower solution concentrations or additions of Cl À alone decreased the corrosion rate of the weldment. The SSC susceptibility, measured as the percentage reduction in area, was maximum in 0.01M NaHCO 3 . Higher or lower solution concentrations of additions of Cl À or SO 2À 4 decreased the SCC susceptibility of the weldment. The amount of hydrogen uptake for the weldment was also highest in 0.01 M NaHCO 3 solution, but it was minimum with the addition of Cl À or SO 2À 4 ions. Thus, the most likely mechanism for the cracking susceptibility of X-52 and X-60 weldments in diluted NaHCO 3 solutions seems to be hydrogen-assisted anodic dissolution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.