A cellulose paper was modified with an aptamer against methamphetamine on either carbon dots (CDs) or on multichannel carbon nanotubes (CNTs). The resulting sorbent was applied to the extraction of METH from blood or saliva. The METH-loaded paper than also was directly applied as a paper spray ionization source in ion mobility spectrometry. The carbon nanomaterial enhances sensitivity, and the aptamer enhances selectivity. The materials were covalently bound to the paper on one side, while the aptamer was immobilized on the other. After optimization of the extraction process and instrumental parameters, the limits of detection when using the aptamer-CNT modified paper are 0.6 ng·mL for saliva, and 0.45 ng·mL for plasma. The respective values when using aptamer-CD modified paper are 1.5 ng·mL for saliva and 0.9 ng·mL for plasma. Calibration plots are linear in the 2 to 150 ng·mL METH concentration range for saliva, and in the 1.5 to 200 ng·mL concentration ranges for blood when using the aptamer-CNT based method. When using the aptamer-CDs, the dynamic ranges extend from 5 to 200 ng·mL and from 3 to 250 ng·mL, respectively. The method was applied to the determination of METH in real samples of saliva and blood, and the accuracy of the method was confirmed by comparison of the results with data analyzed by GC-MS. Graphical abstract ᅟ.
A selective thin-film microextraction based on aptamer immobilized on cellulose paper was used as a paper spray ionization source for ion mobility spectrometry (PSI-IMS), for the first time. In this method, the paper is not only used as an ionization source but also it is utilized for the selective extraction of analyte, based on immobilized aptamer. This combination integrates both sample preparation and analyte ionization in a Whatman paper. To that end, an appropriate sample introduction system with a novel design was constructed for the paper spray ionization source. Using this system, a continuous solvent flow works as an elution and spray solvent simultaneously. In this method, analyte is adsorbed on a triangular paper with immobilized aptamer and then it is desorbed and ionized by elution solvent and applied high voltage on paper, respectively. The effects of different experimental parameters such as applied voltage, angle of paper tip, distance between paper tip and counter electrode, elution solvent type, and solvent flow rate were optimized. The proposed method was exhaustively validated in terms of sensitivity and reproducibility by analyzing the standard solutions of codeine and acetamiprid. The analytical results obtained are promising enough to ensure the use of immobilized aptamer paper-spray as both the extraction and ionization techniques in IMS for direct analysis of biomedicine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.