We have developed a refined computer-based method to detect joint space narrowing (JSN) progression with the joint space narrowing progression index (JSNPI) by superimposing sequential hand radiographs. The purpose of this study is to assess the validity of a computer-based method using images obtained from multiple institutions in rheumatoid arthritis (RA) patients. Sequential hand radiographs of 42 patients (37 females and 5 males) with RA from two institutions were analyzed by a computer-based method and visual scoring systems as a standard of reference. The JSNPI above the smallest detectable difference (SDD) defined JSN progression on the joint level. The sensitivity and specificity of the computer-based method for JSN progression was calculated using the SDD and a receiver operating characteristic (ROC) curve. Out of 314 metacarpophalangeal joints, 34 joints progressed based on the SDD, while 11 joints widened. Twenty-one joints progressed in the computer-based method, 11 joints in the scoring systems, and 13 joints in both methods. Based on the SDD, we found lower sensitivity and higher specificity with 54.2 and 92.8%, respectively. At the most discriminant cutoff point according to the ROC curve, the sensitivity and specificity was 70.8 and 81.7%, respectively. The proposed computer-based method provides quantitative measurement of JSN progression using sequential hand radiographs and may be a useful tool in follow-up assessment of joint damage in RA patients.
Background Recent papers suggest that finger joints with positive synovial vascularity (SV) assessed by ultrasonography under clinical low disease activity (CLDA) in rheumatoid arthritis (RA) patients may cause joint space narrowing (JSN) progression. Purpose To investigate the performance of a computer-based method by directly comparing with the conventional scoring method in terms of the detectability of JSN progression in hand radiography of RA patients with CLDA. Material and Methods Fifteen RA patients (13 women, 2 men) with long-term sustained CLDA of >2 years were included. Radiological progression of finger joints was measured or scored using the computer-based method which can detect JSN progression between two radiographic images as the joint space difference index (JSDI), as well as the Genant-modified Sharp score (GSS). We also quantitatively assessed SV of these joints using ultrasonography. Results Out of 270 joints, we targeted 259 finger joints after excluding nine damaged joints (four ankylosis, three complete luxation, and two subluxation) and two improved joints according to the GSS results. The JSDI of finger joints with JSN progression was significantly higher than those without JSN progression ( P = 0.018). The JSDI of finger joints with ultrasonographic SV was significantly higher than those without ultrasonographic SV ( P = 0.004). Progression in JSDI showed stronger associations with ultrasonographic SV than progression in GSS (odds ratio [95% confidence interval]: 7.19 [3.37-15.36] versus 5.84 [2.76-12.33]). Conclusion The computer-based method was comparable to the conventional scoring method regarding the detectability of JSN progression in RA patients with CLDA.
The visual assessment of joint space narrowing (JSN) on radiographs of rheumatoid arthritis (RA) patients such as the Genant-modified Sharp score (GSS) is widely accepted but limited by its subjectivity and insufficient sensitivity. We developed a software application which can assess JSN quantitatively using a temporal subtraction technique for radiographs, in which the chronological change in JSN between two radiographs was defined as the joint space difference index (JSDI). The aim of this study is to prove the superiority of the software in terms of detecting fine radiographic progression in finger JSN over human observers. A micrometer measurement apparatus that can adjust arbitrary joint space width (JSW) in a phantom joint was developed to define true JSW. We compared the smallest detectable changes in JSW between the JSDI and visual assessment using phantom images. In a clinical study, 222 finger joints without interval score change on GSS in 15 RA patients were examined. We compared the JSDI between joints with and without synovial vascularity (SV) on power Doppler ultrasonography during the follow-up period. True JSW difference was correlated with JSDI for JSW differences ranging from 0.10 to 1.00 mm at increments of 0.10 mm (R
2
= 0.986 and P < 0.001). Rheumatologists were difficult to detect JSW difference of 0.30 mm or less. The JSDI of finger joints with SV was significantly higher than those without SV (P = 0.030). The software can detect fine differences in JSW that are visually unrecognizable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.