During activity of daily living involving standing, sitting or maneuvering, humans are typically susceptible to neck and shoulder strain, and other musculoskeletal conditions, severity of which may lead to posture deformity. To prevent these clinical conditions, we developed a low-cost and user-friendly posture monitor mainly built on a single flex sensor. The design was based on abnormal posture detection by a flex sensor whose signal triggers a buzzer to notify the user or care giver of these clinical conditions. Through Arduino IDE, an ATmega328 microcontroller controlled the sequence of the flex sensing to the audible alarm output. The buzzer was designed to go off automatically when the user adjusts his/her posture to normalcy. With a sensitivity of 84.6% during testing of this device, the developed posture monitoring device could be adjudged effective and suitable to monitor people's posture while sitting or standing especially in environments where menial jobs are prevalent. In these individuals, this device may prevent deformity prone diseases that may warrant surgical intervention for correction.
A glucometer is an important device used to monitor blood glucose level of diabetes patients to prevent degenerated health conditions. The conventional glucometers are characterized by piercing of the sample site for patients’ testing. The invasive nature of these glucometers is painful to the patients and some patients are also scared at the sight of blood. To promote glucometer acceptance among patients, it is important to develop a non-invasive glucometer using acetone gas sensor with “exhaled breath” collected non-invasively as the sample for the glucometer. After the device development, exhaled breath sample of twenty subjects with age range of 20 to 55 years from a University were taken using the developed acetone sensor device. Prior to the exhaled breath sample collection, the blood glucose levels of the volunteered subjects were also determined using the conventional and proprietary invasive clinical method. To infer whether there is significant different between the mean of the results obtained from the conventional and the exhaled breath method, a t-test was carried out on the results and P values of 0.9860 and 0.9306 were obtained for fasting blood sugar and random blood sugar respectively, indicating no significant differences in the results obtained from the developed device when compared with the proprietary device. Hence, non-invasive glucometer using acetone gas sensor can be used to promote inexpensive personalized diabetes monitoring without inflicting pain on the patients. Promotion of this device could also reduce the expenses incurred on lancet and test strips, thus, making it suitable for low income earners.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.