Wandering spleen is a rare clinical entity, and its chronic torsion of the vascular pedicle result in splenic vein occlusion leading to gastric varices. Here, we present a case of wandering spleen complicating gastric varices in a 40-year-old female. Three-dimensional CT (3D-CT) clearly showed the disruption of the splenic vein at the origin of the vascular pedicle and collateral development of the gastric varices. The patient was electively treated with laparoscopic splenectomy. Difficulty of prediction of the splenic vein recanalization to improve the varices was the reason for the use of splenectomy versus splenopexy. The varices were successfully diminished 3 months after the surgery. After review of cases of complicating gastric varices in the literatures, splenectomy is still a secure way to treat an adult patient with wandering spleen with complicating gastric varices.
Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection.
Background: Technical factors leading to hernia recurrence after transabdominal preperitoneal repair include insufficient dissection, inadequate prosthetic overlap and prosthetic size, improper fixation and folding, or crinkling of the prosthesis. However, determining intraoperatively if a case will develop recurrent hernias due to these factors remains unclear. Methods: Five surgeons blind-reviewed operation videos of primary laparoscopic hernioplasty in 13 lesions that went on to develop recurrent hernias (i.e., future recurrence), as well as 28 control lesions, to assess twelve items of surgical techniques. Since we changed a surgical policy of covering myopectineal orifice (MPO) in April 2003, we analyzed the data for the earlier and later periods. The data was analyzed with hierarchical clustering to obtain a gross grouping. The differences of the ratings between the future recurrent and control lesions were then analyzed and the association of the techniques with the hernia recurrence rate, the size of the prosthesis, and the hernia type across hernia recurrence were explored. Results: The lesions were grouped based on the time series, and its boundary was approximated when we changed our surgical policy. This policy change caused ratings to progress from 34% satisfactory, to 79% satisfactory. The recurrence rate decreased to 0.7% (5/678), compared with 6.2% (10/161) before the policy was implemented (p < 0.001). With univariate analysis, the ratings of posterior prosthesis overlap to the MPO in the recurrent lesions were significantly lower than controls in the later period (p = 0.019). Although various types of recurrences were noted in the earlier period, only primary indirect and recurrent indirect hernias were observed in the later period (p = 0.006). Conclusions: Fully covering the MPO with mesh is essential for preventing direct recurrence hernias. Additional hernia recurrence prevention can be obtained by giving appropriate attention to prosthesis overlap posterior to the MPO in a large indirect hernia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.