Washout of 10C and 11C implanted by radioactive beams in brain and thigh muscle of rabbits was studied. The biological washout effect in a living body is important in the range verification system or three-dimensional volume imaging in heavy ion therapy. Positron emitter beams were implanted in the rabbit and the annihilation gamma-rays were measured by an in situ positron camera which consisted of a pair of scintillation cameras set on either side of the target. The ROI (region of interest) was set as a two-dimensional position distribution and the time-activity curve of the ROI was measured. Experiments were done under two conditions: live and dead. By comparing the two sets of measurement data, it was deduced that there are at least three components in the washout process. Time-activity curves of both brain and thigh muscle were clearly explained by the three-component model analysis. The three components ratios (and washout half-lives) were 35% (2.0 s), 30% (140 s) and 35% (10 191 s) for brain and 30% (10 s), 19% (195 s) and 52% (3175 s) for thigh muscle. The washout effect must be taken into account for the verification of treatment plans by means of positron camera measurements.
A project to construct a new treatment facility as an extension of the existing heavy-ion medical accelerator in chiba (HIMAC) facility has been initiated for further development of carbon-ion therapy. The greatest challenge of this project is to realize treatment of a moving target by scanning irradiation. For this purpose, we decided to combine the rescanning technique and the gated irradiation method. To determine how to avoid hot and/or cold spots by the relatively large number of rescannings within an acceptable irradiation time, we have studied the scanning strategy, scanning magnets and their control, and beam intensity dynamic control. We have designed a raster scanning system and carried out a simulation of irradiating moving targets. The result shows the possibility of practical realization of moving target irradiation with pencil beam scanning. We describe the present status of our design study of the raster scanning system for the HIMAC new treatment facility.
Heavy ion therapy has two definite advantages: good dose localization and higher biological effect. Range calculation of the heavy ions is an important factor in treatment planning. X-ray CT numbers are used to estimate the heavy ion range by looking up values in a conversion table which relates empirically photon attenuation in tissues to particle stopping power; this is one source of uncertainty in the treatment planning. Use of positron emitting radioactive beams along with a positron emission tomograph or a positron camera gives range information and may be used as a means of checking in heavy ion treatment planning. However, the metabolism of the implanted positron emitters in a living object is unpredictable because the chemical forms of these emitters are unknown and the metabolism is dependent on the organ species and may be influenced by many factors such as blood flow rate and fluid components present. In this paper, the washout rate of 11C activity implanted by injecting energetic 11C beams into thigh muscle of a rear leg of a rabbit is presented. The washout was found to consist of two components, the shorter one was about 4.2 +/- 1.1 min and the longer one ranged from 91 to 124 min. About one third of the implanted beta+ activity can be used for imaging and the rest was washed out of the target area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.