ObjectiveAmong people with Marfan syndrome who have a typical aortic root aneurysm, dissection is a characteristic cause of premature death. To pre-empt Type A dissection, composite root replacement with a mechanical valve became the standard of care in the 1980s and 1990s. This is being superseded by valve-sparing aortic root replacement to avoid lifelong anticoagulation. In 2004, a total root and valve-sparing procedure, personalised external aortic support, was introduced. We report here results among the first 30 recipients.MethodsFrom cross-sectional digital images, the patient's own aorta is modelled by computer aided design and a replica is made in thermoplastic by rapid prototyping. On this, a personalised support of a macroporous polymer mesh is manufactured. The mesh is positioned around the aorta, closely applied from the aortoventricular junction to beyond the brachiocephalic artery. The operation is performed with a beating heart and usually without cardiopulmonary bypass.ResultsBetween 2004 and 2011, 30 patients, median age 28 years (IQR 20–44) had this operation and have been prospectively followed for 1.4–8.8 years by February 2013. During a total of 133 patient-years there were no deaths or cerebrovascular, aortic or valve-related events. These early outcomes are better than published results for the more radical extirpative root replacement operations.ConclusionsThe aortic valve, the root architecture, and the blood/endothelia interface are conserved. The perioperative burden is less and there has been freedom from aortic and valvular events. A prospective comparative study is planned.
Fatal aortic dissection commonly occurs in Marfan syndrome. Prevention currently relies on elective replacement of the aortic root. We are evaluating the placement of a manufactured, bespoke external support derived from a computer aided design in a prospective study. In the first ten patients, measurements were made consistently of the ascending aorta at the level of closure of the aortic valve cusps from magnetic resonance imaging (MRI) studies taken preoperatively and at fixed intervals thereafter. Before and after images were presented for measurement amongst duplicate images of 37 unoperated Marfan patients to permit assessment of intra-observer measurement reproducibility. All images were presented in random sequence to a radiologist unaware of the research question. The largest difference between the preoperative measurement and that made at least one year after surgery was determined. All patients had surgery as planned without complications and were alive at one year. In eight of the ten patients, the largest observed change was a marked reduction in aortic root diameter. The primary objective of this surgery was achieved in each case, reinforcing the ascending aorta whilst leaving the native aortic valve intact and conserving the blood/endothelium interface.
ObjectiveThe study is an early phase of development of a decision support framework for people with Marfan syndrome who are anticipating prophylactic aortic root surgery. Implications of the timing and the nature of the operation chosen were previously elicited in focus groups. In this step, we explored the range of relative values placed by individuals on the implications of decisions made about surgery.MethodsFollowing the principles of the Ottawa Decision Support Framework, eight questions in the general form ‘How important is it to you …’ were framed by a panel. Marfan people, families and specialist doctors answered online. Quantitative and qualitative analyses were performed.ResultsWorldwide, 142 responses were received including 25 specialist doctors. Respondents were 55% female and 46% had previous aortic root surgery. Overall, active lifestyle was more important to males (p=0.03). Patients placed more importance than doctors on not deferring surgery (p=0.04) and on avoidance of anticoagulation in the interests of childbearing (p=0.009). Qualitative analysis showed differing but cogently reasoned values that were sometimes polarised, and mainly driven by the wish to maintain a good quality of life and active lifestyle.ConclusionsGiven the cogency of these viewpoints, people anticipating root replacement surgery should have ample opportunity to express them and to have them acknowledged ahead of a consultation when they can then be fully explored in a mutually informed forum. If they differ from local medical practice, they can then be discussed in the process of reaching shared and individualised decisions.
Background and objectivesIn personalised external aortic root support (PEARS), a custom-made, macroporous mesh is used to stabilise a dilated aortic root and prevent dissection, primarily in patients with genetically driven aortopathies. Data are needed on the safety and postoperative incidence of aortic events.MethodsWe present a multicentre cohort study evaluating the first 200 consecutive patients (median age 33 years) undergoing surgery with an intention to perform PEARS for aortic root dilatation in 23 centres between 2004 and 2019. Perioperative outcomes were collected prospectively while clinical follow-up was retrieved retrospectively. Median follow-up was 21.2 months.ResultsThe main indication was Marfan syndrome (73.5%) and the most frequent concomitant procedure was mitral valve repair (10%). An intervention for myocardial ischaemia or coronary injury was needed in 11 patients, 1 case resulting in perioperative death. No ascending aortic dissections were observed in 596 documented postoperative patient years. Late reoperation was performed in 3 patients for operator failure to achieve complete mesh coverage. Among patients with at least mild aortic regurgitation (AR) preoperatively, 68% had no or trivial AR at follow-up.ConclusionsThis study represents the clinical history of the first 200 patients to undergo PEARS. To date, aortic dissection has not been observed in the restrained part of the aorta, yet long-term follow-up is needed to confirm the potential of PEARS to prevent dissection. While operative mortality is low, the reported coronary complications reflect the learning curve of aortic root surgery in patients with connective tissue disease. PEARS may stabilise or reduce aortic regurgitation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.