Left ventricular assist devices have provided successful supportive therapy for patients awaiting cardiac transplantation for extended periods of time. Although thromboembolic events have complicated support with these devices, the HeartMate left ventricular assist device developed by Thermo Cardiosystems, Inc., Woburn, Massachusetts, was specifically designed with a textured blood-contacting surface to minimize this risk. Clinical experience with this device has been encouraging, inasmuch as minimal thromboembolic complications have occurred despite the absence of anticoagulation. The coagulation and fibrinolytic pathways in these individuals were investigated to better understand the hematologic status of patients treated with the Thermo Cardiosystems device. Despite apparently normal prothrombin and activated partial thromboplastin times, as well as platelet counts, evidence of significant thrombin generation and fibrinolysis was present. To eliminate underlying cardiac failure as the responsible factor for these abnormalities, we made similar measurements in patients with end-stage heart failure who were not supported by an assist device or anticoagulation. These measurements revealed no evidence of thrombin generation or fibrinolysis. These data demonstrate that patients supported with a left ventricular assist device, while successfully sustained without systemic anticoagulation, nevertheless have evidence of activation of coagulation. These phenomena appear to be related to the presence of the device rather than to the underlying cardiac abnormalities. Although procoagulant and fibrinolytic pathways are apparently balanced in these patients, these data underscore the potential for the development of bleeding or thrombosis in clinically relevant settings.
Background-Solid organ donors often develop hypotension due to vasodilation, and recently we observed that a variety of vasodilatory states are characterized by vasopressin deficiency and hypersensitivity. Thus, we investigated the prevalence of vasopressin deficiency in hypotensive solid organ donors without clinical evidence of diabetes insipidus; we also investigated the vasopressor effect of vasopressin replacement in hypotensive donors. Methods and Results-Fifty organ donors were evaluated for hemodynamic instability, (mean arterial pressure [MAP]Յ 70 mm Hg despite the use of catecholamine vasopressors), and in those unstable donors who were not already receiving exogenous vasopressin, low-dose vasopressin was administered as a continuous infusion (0.04 to 0.1 U/min). MAP, catecholamine requirements, serum vasopressin, and serum osmolality were obtained before and after vasopressin administration. Ten patients meeting the enrollment criteria received vasopressin and MAP increased from 72.2Ϯ3.5 to 89.8Ϯ4.2 mm Hg, (PϽ0.05), allowing for complete discontinuation of catecholamine pressors in 4 (40%) patients and a decrement in pressor dose in 4 (40%). Plasma vasopressin levels (2.9Ϯ0.8 pg/mL) were low for the degree of hypotension. Conclusions-Hemodynamically unstable organ donors without clinically apparent diabetes insipidus display a defect in the baroreflex-mediated secretion of vasopressin. In these patients, low-dose vasopressin significantly increases blood pressure with a pressor response sufficient to reduce catecholamine administration. (Circulation. 1999;100[suppl II]:II-244-II-246.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.