The flushing of toilets generates contaminated aerosols, the transmission of which may cause the spread of disease, particularly in the immunocompromised or the elderly. This study investigated the emission strength of three types of airborne bacteria, namely Staphylococcus epidermidis, Escherichia coli, and Pseudomonas alcaligenes, during toilet flushing in a custom-built toilet under a controlled environment. Flushing was activated by a flushometer operated at two pressure levels, 400 kPa (high pressure [HP]) and 200 kPa (low pressure [LP]), and by a water cistern tank placed 95 cm (high tank [HT]) and 46 cm (low tank [LT]) above the toilet seat. The pathogens emitted by the first flush were calculated, with the correlations between airborne pathogen emissions and droplet concentration (HP, r=0.944, P<.001; LP, r=0.803, P<.001, HT, r=0.885, P<.05) and bacterial size (HP, r=-0.919, P<.001; LP, r=-0.936, P<.001; HT, r=-0.967, P<.05) in the different conditions then tested. The emission strength in the HP condition was statistically greater than that in the LP condition, whereas the cistern tank system produced less emissions than the flushometer system, and tank height was not found to be a sensitive parameter.
The process of toilet-flushing can generate flushing-associated water droplets which can potentially expose humans to pathogen-laden aerosols. Very little is known about such aerosol dissemination or the means for minimizing exposure to these aerosols. This study has evaluated the efficacy of ultraviolet waveband C (UV-C) for disinfection of flushing-generated pathogen-laden aerosols through tests with localized disinfection systems for airborne and surface contaminations. Three types of bacteria were chosen for investigation: Staphylococcus epidermidis, Escherichia coli, and Salmonella typhimurium. Tests were conducted with UV-C tubes of 5 W and 10 W. High levels of disinfection efficacies were observed, ranging from 76% to 97% for bacteria-laden aerosols at sources of emission, and efficiencies of 53% to 79% for surface samples in localized systems. The results from the localized systems were further compared with those obtained with an upper-room ultraviolet germicidal irradiation (UVGI) system. As it is important to note, the UV-C doses and ozone emissions for the localized systems were found well below the limits recommended in current guidelines. This research has shown that the disinfection of flushing-generated pathogen-laden aerosols in proximity to the source of emission was more effective than at the more distant sites where aerosols may be dispersed to the environment.
Decomposition characteristics of two groups of representative mixed malodorants (1, ethanethiol + hydrogen sulfide; 2, ethanethiol + ammonia) in air were investigated employing a wire-plate pulse corona reactor. A new type of high-voltage pulse generator with a thyratron switch and a Blumlein pulse-forming network (BPFN) was used in our experiments. The experiments were conducted at a gas-flow rate of 13 m3/h. Important parameters, including peak voltage, chemical structures of malodorants, pulse frequency, and initial concentration, which influenced the removal efficiency, were investigated. The results showed that the mixed malodorants could be treated effectively by pulse corona. The removal efficiencies of 200 mg/m3 C2H5SH and 200 mg/m3 H2S for group 1 were 95.6% and 100%, respectively, which were almost equal to those of the two pollutants separately. The energy cost was about 65.1-81.4 J/L, which was 31.5-45.2% lower than for treating pollutants alone. The removal efficiencies of 105 mg/m3 C2HsSH and 40 mg/m3 NH3 for group 2 were 93.1% and almost 100%, and the energy cost was 65.1 J/L, 55.6% lower than that which was treated separately. In the case of two groups of mixed malodorants removal, NOx, 03, SO2, CO2, and CO were all observed. Moreover, some sulfur and white crystal ammonium nitrates were discovered adhering to the corona wires in the removal of groups 1 and 2, respectively. A dynamics model was developed to describe the relation of the removal efficiency with specific energy density and initial concentration. In the case of group 1 removal,the decomposition rate constants decreased as compared to the single treating. As for group 2 removal, the decomposition rate constants increased, especially for NH3. According to the results, the optimization design for the reactor and the matching of high pulse voltage source can be reckoned.
This article introduces the EU Horizon 2020 research project MIX-UP, “Mixed plastics biodegradation and upcycling using microbial communities”. The project focuses on the ambitious vision to change the traditional linear value chain of plastics to a sustainable, biodegradable based one. In MIX-UP, plastic mixtures containing five of the top six fossil-based recalcitrant plastics (PE, PUR, PP, PET, and PS), along with upcoming biobased and biodegradable plastics (bioplastics) such as PHA and PLA, will be used as feedstock for microbial transformations. The generated new workflow increases recycling quotas and adds value to present poorly recycled plastic waste streams. Consecutive controlled enzymatic and microbial degradation of mechanically pre-treated plastics waste combined with subsequent microbial conversion to polymers and value-added chemicals by mixed cultures. Through optimization of known plastic-degrading enzymes by integrated protein engineering, high specific binding capacities, stability, and catalytic efficacy towards a broad spectrum of plastic polymers under high salt content and temperature conditions will be achieved. Another focus lies in the search and isolation of novel enzymes active on recalcitrant polymers. MIX-UP will also enhance the production of enzymes and formulate enzyme cocktails tailored to specific waste streams. In vivo and in vitro application of these cocktails enables stable, self-sustaining microbiomes to convert the released plastic monomers selectively into value-added products, key building blocks, and biomass. Any of the remaining material recalcitrant to the enzymatic activity will be recirculated into the process by physicochemical treatment. The Chinese-European MIX-UP is a multidisciplinary and industry-participating consortium to address the market need for novel sustainable routes to valorize plastic waste streams. MIX-UP realizes a circular (bio) plastic economy and will contribute where mechanical and chemical plastic recycling show limits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.