Phase-shifting is one of the most useful methods of phase recovery in digital interferometry in the estimation of small displacements, but miscalibration errors of the phase shifters are very common. In practice, the main problem associated with such errors is related to the response of the phase shifter devices, since they are dependent on mechanical and/or electrical parts. In this work, a novel technique to detect and measure calibration errors in phase-shifting interferometry, when an unexpected phase shift arises, is proposed. The described method uses the Radon transform, first as an automatic-calibrating technique, and then as a profile measuring procedure when analyzing a specific zone of an interferogram. After, once maximum and minimum value parameters have been registered, these can be used to measure calibration errors. Synthetic and real interferograms are included in the testing, which has thrown good approximations for both cases, notwithstanding the interferogram fringe distribution or its phase-shifting steps. Tests have shown that this algorithm is able to measure the deviations of the steps in phase-shifting interferometry. The developed algorithm can also be used as an alternative in the calibration of phase shifter devices.
Due to the physical nature of the interference phenomenon, extracting the phase of an interferogram is a known sinusoidal modulation problem. In order to solve this problem, a new hybrid mathematical optimization model for phase extraction is established. The combination of frequency guide sequential demodulation and harmony search optimization algorithms is used for demodulating closed fringes patterns in order to find the phase of interferogram applications. The proposed algorithm is tested in four sets of different synthetic interferograms, finding a range of average relative error in phase reconstructions of 0.14–0.39 rad. For reference, experimental results are compared with the genetic algorithm optimization technique, obtaining a reduction in the error up to 0.1448 rad. Finally, the proposed algorithm is compared with a very known demodulation algorithm, using a real interferogram, obtaining a relative error of 1.561 rad. Results are shown in patterns with complex fringes distribution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.