Purpose: To compare incision size enlargement at different times of cataract surgery and visual outcomes after surgery in 2 different intraocular lens (IOL) delivery systems (Vivinex iSert and UltraSert Preloaded IOL Delivery System). Setting: Tertiary care eye institution. Design: Prospective nonrandomized comparison study. Methods: All eyes had uneventful temporal clear corneal phacoemulsification cataract surgery. The surgery was done by standard direct horizontal chop with a bimanual irrigation aspiration of the cortex. The primary incision size was measured after clear corneal incision, after the completion of phacoemulsification, and after IOL implantation. Results: The study comprised 276 eyes of 220 patients. The mean initial corneal incision was similar in both groups (2.2 mm). There was no significant difference in the mean incision size after phacoemulsification between the 2 groups (2.250 mm ± 0.068 mm [SD] vs 2.251 ± 0.066 mm [SD], P > .99). There was no significant difference in the mean (SD) incision size after IOL insertion between the 2 groups (2.367 ± 0.066 mm vs 2.369 ± 0.062 mm [SD], P = .815. The corrected distance visual acuity was 6/6 at 1 month in 80% of the participants in the UltraSert group and 86% in the Vivinex group. After adjusting for age, sex, grade of cataract, and IOL power, no significant difference was found in the magnitude of surgically induced astigmatism (SIA) in the Vivinex group compared with the UltraSert group (0.06, 95% CI, −0.11 to 0.24; P = .47). Conclusions: No significant difference was found in the change in the incision size, visual acuity, and SIA between UltraSert and Vivinex IOL delivery systems. This suggests that both IOL delivery systems are comparable in terms of post-IOL delivery incision enlargement for incisions of 2.2 mm.
Introduction: The present study compared visual outcomes in eyes with bilateral implantation of two multifocal intraocular lenses (MFIOLs)-the Eyecryl TM ACTV diffractive multifocal IOL (group 1) and AcrySof Ò IQ ReSTOR Ò multifocal IOL (group 2). Methods: This was a prospective, two-group observational longitudinal study of 118 eyes from 59 patients conducted at Laxmi Eye Institute, Panvel, India. We evaluated the patients at 1, 3, and 6 months. We assessed visual acuity, contrast sensitivity, higher-order aberrations, reading speed, defocus curve, stereopsis, quality of life (QOL), and adverse events in these participants. Results: The median (interquartile range) bestcorrected distance visual acuity was 0.18 (0, 0.18) in group 1 and 0.18 (0, 0.18) in group 2 at 1, 3, and 6 months; the difference was not statistically significant (p = 0.48). The binocular defocus curve in both groups showed two peaks at 0.0 to-0.5 D and at-2.5 D. The mean (95% confidence interval) critical print size was significantly different between groups 1 and 2 at low illumination (0.918 [0.905, 0.931] vs 1.154 [1.128, 1.180]; p = 0.004). Contrast sensitivity was significantly better in group 1 under mesopic conditions but not under scotopic conditions. Though total QOL did not differ significantly between groups, the psychosocial quality of life was significantly better in group 1. About 23% of patients in group 2 reported unwanted images, compared with 0% in group 1 (p = 0.01). Conclusion: We found that the Eyecryl and AcrySof groups were comparable for best-corrected visual acuity, photopic contrast sensitivity, defocus curve, reading parameters, stereopsis, and quality of vision. However, the Eyecryl group had better mesopic contrast and a lower proportion of unwanted images. Psychosocial quality of life was significantly better in the Eyecryl group; however, satisfaction was similar between groups. The cost of one of the lenses is less than the other. Thus, individuals with limited resources may opt for the Eyecryl TM ACTV, with similar visual outcomes.
Purpose: To evaluate the diagnostic test properties of the Palm Scan VF2000® Virtual Reality Visual Field Analyzer for diagnosis and classification of the severity of glaucoma. Methods: This study was a prospective cross-sectional analysis of 166 eyes from 97 participants. All of them were examined by the Humphrey® Field Analyzer (used as the gold standard) and the Palm Scan VF 2000® Virtual Reality Visual Field Analyzer on the same day by the same examiner. We estimated the kappa statistic (including 95% confidence interval [CI]) as a measure of agreement between these two methods. The diagnostic test properties were assessed using sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: The sensitivity, specificity, PPV, and NPV for the Virtual Reality Visual Field Analyzer for the classification of individuals as glaucoma/non-glaucoma was 100%. The general agreement for the classification of glaucoma between these two instruments was 0.63 (95% CI: 0.56–0.78). The agreement for mild glaucoma was 0.76 (95% CI: 0.61–0.92), for moderate glaucoma was 0.37 (0.14–0.60), and for severe glaucoma was 0.70 (95% CI: 0.55–0.85). About 28% of moderate glaucoma cases were misclassified as mild and 17% were misclassified as severe by the virtual reality visual field analyzer. Furthermore, 20% of severe cases were misclassified as moderate by this instrument. Conclusion: The instrument is 100% sensitive and specific in detection of glaucoma. However, among patients with glaucoma, there is a relatively high proportion of misclassification of severity of glaucoma. Thus, although useful for screening of glaucoma, it cannot replace the Humphrey® Field Analyzer for the clinical management in its current form.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.